White Papers

Version 1.4.0 17
Property Name
Requirements
Type
Requirement and Description
SystemID
Mandatory
uint32
System ID describes the model of the system
in integer value. The SystemID property is
usually used to identify the compatibility of the
updateable software/firmware.
SystemRevision
Mandatory
uint16
System Revision describes whether the
platform was the first or second revision of the
corresponding model. The revisions are
usually correlated with an upgrade of the CPU
model in the same platform model.
TempRollupStatus
Mandatory
uint32
The property shall contain the temperature
rollup status of all the system components
and shall contain one of the following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
TempRollupStatus provides a high level
status value, intended to align with Red-
Yellow-Green type representation of status.
UUID
Mandatory
string
UUID uniquely identifies the system. The
property is also known as BIOS GUID.
The UUID value matces the WMI®
representation of the UUID/GUID.
VoltRollupStatus
Mandatory
uint32
The property shall contain the voltage rollup
status of all the system components and shall
contain one of the following values:
0(Unknown)
1(OK)
2(Degraded)
3(Error).
VoltRollupStatus provides a high level status
value, intended to align with Red-Yellow-
Green type representation of status.
LastSystemInventoryTime
Mandatory
string
This property provides the last time \System
\Inventory Collection On Reboot(CSIOR)\
was performed. The value is represented as
yyyymmddHHMMSS.
LastUpdateTime
Mandatory
string
This property provides the last time the data
was updated. The value is represented as
yyyymmddHHMMSS
278
279