August 2012
Statement of Volatility Dell U2713HM Monitor
CAUTION: A CAUTION indicates either potential damage to hardware or loss of data and tells you how to avoid the
problem.
The Dell U2713HM Flat Panel Monitor contains both volatile and non-volatile (NV) components. Volatile components lose
their data immediately after power is removed from the component. Non-volatile (NV) components continue to retain their
data even after power is removed from the component. The following NV components are present on the U2713HM system
board.
Table 1. List of Non-Volatile Components on System Board
Description
Reference
Designator
Volatility Description
User
Accessible
for external
data
Remedial Action (Action
necessary to prevent loss of
data)
Serial flash
memory
25LD040
I308 Non Volatile memory, 4M
bites. To store firmware.
No Part of Interface board
assembly, software write
protected
DP EDID
and HDCP
EEPROM
M24C32
I307
Non Volatile memory, 32k
bites.
No
Part of Interface board
assembly,
hardware write
protected
DDR 3
SDRAM
NT5CB64
M16DP
I309
Volatile memory 64 x 16 Mbit
in OFF state.
NOTE:
Buffer of video decoder
No
Part of Interface board
assembly,
No write protect
mechanism
VGA
EDID
EEPROM
24C02
I316 Non Volatile memory, 2Kbit,
To store VGA EDID.
No
Part of Interface board
assembly,
hardware write
protected
DVI EDID
EEPROM
24C02
I304
Non Volatile memory, 2Kbit, To
store DVI EDID.
No
Part of Interface board
assembly,
hardware write
protected
HDMI
EDID
EEPROM
24C02
I305
Non Volatile memory, 2Kbit, To
store HDMI EDID
No
Part of Interface board
assembly,
hardware write
protected
CAUTION: All other components on the system board lose data if power is removed from the system. Primary power
loss (unplugging the power cord and removing the battery) destroys all user data on the memory (DDR3, 1067 MHz).
Secondary power loss (removing the on-board coin-cell battery) destroys system data on the system configuration
and time-of-day information.