If you choose an external drives PCIe RAID controller (Cisco 12G SAS 9300-8e HBA), it will
consume one PCIe slot.
A maximum of two or three storage accelerator cards are supported (riser option
dependent) and they must be installed in riser 1 only. The Cisco 12G SAS 9300-8e also can
only be installed in riser 1; therefore if you install a Cisco 12G SAS 9300-8e, it must displace
one of the storage accelerator cards.
For 1-CPU systems:
Only the PCIe slots on PCIe riser 1 are available for 1-CPU system.
The PCIe slots on riser 2 are not supported on 1-CPU systems. The slots are
full-height PCIe slots 4, 5, and 6 (see
Figure 5 on page 9). These are the slots on
the right when looking at the rear of the server.
10 Gb Converged Network Adapters (CNAs)
UCSC-PCIE-E14102 Emulex OCe14102-UX dual-port 10 GbE FCoE CNA Half
Host Bus Adapters (HBAs)
N2XX-AQPCI05 Qlogic QLE2562 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-Q2672 Qlogic QLE2672-CSC, 16Gb Fibre Channel HBA with SR Optics Half
N2XX-AEPCI05 Emulex LPe 12002 Dual Port 8Gb Fibre Channel HBA Half
UCSC-PCIE-E16002 Emulex LPe16002-M6, 16Gb Fibre Channel HBA with SR Optics Half
UCS Storage Accelerators
3
UCSC-F-FIO-1000PS UCS 1000 GB Fusion ioMemory3 PX Performance line for C-Series Half
UCSC-F-FIO-1300PS UCS 1300 GB Fusion ioMemory3 PX Performance line for C-Series Half
UCSC-F-FIO-2600PS UCS 2600 GB Fusion ioMemory3 PX Performance line for C-Series Half
UCSC-F-FIO-5200PS UCS 5200 GB Fusion ioMemory3 PX Performance line for C-Series Full
UCSC-F-FIO-3200SS UCS 3200GB Fusion ioMemory3 SX Scale line for C-Series Half
UCSC-F-FIO-6400SS UCS 6200GB Fusion ioMemory3 SX Scale line for C-Series Full
Notes . . .
1. The mLOM cards do not plug into any of the riser 1 or riser 2 card slots; instead, they plug into a connector
inside the server chassis.
2. These cards and the GPU cards (see ORDER GPU CARDS(OPTIONAL), page 42) must be inserted into a full
length x16 (electrical) PCIe slot. See Riser Card Configuration and Options, page 70 for more details. The
rest of the PCIe cards are x8 (electrical) and can be plugged into any PCIe slot of riser 1 or riser 2.
3. A maximum of two or three storage accelerator cards (riser option dependent) are supported and they must be
installed in riser 1 only. The Cisco 12G SAS 9300-8e also can only be installed in riser 1; therefore if you install
a Cisco 12G SAS 9300-8e, it must displace one of the storage accelerator cards.