Owner's Manual
file:///T|/htdocs/SOFTWARE/smdup/dup65/EN/readme/lin/lin_read.txt[10/23/2012 10:39:00 AM]
attempting to run a Dell Update Package from a USB flash drive
under Linux, and are experiencing problems, remount the drive
without the "-noexec" option, or copy the Dell Update Package to a
drive mounted without the "-noexec" option.
* Dell Update Packages do not require new refreshes of existing DUPs
to be reinstalled since the firmware or driver payload does not
change when the DUP is refreshed. A new DUP is available if changes
have been made to the firmware or driver payload.
* If the console terminal displays USB connection status messages,
ignore them as they do not affect the system.
* On all versions of ESX the following the USB Connection message with
errors, these messages can also be ignored. The following shows a
typical message:
Vendor: iDRAC Model: MAS022 Rev: 1.00
Type: Direct-Access ANSI SCSI revision: 02
VMWARE SCSI Id: Supported VPD pages for sdc : 0x1f
VMWARE SCSI Id: Could not get disk id for sdc
VMWARE: Unique Device attached as scsi disk sdc at scsi3, channel 0,
id 0, lun 0
Attached scsi removable disk sdc at scsi3, channel 0, id 0, lun 0
SCSI device sdc: 327680 512-byte hdwr sectors (168 MB)
sdc: Write Protect is on
SCSI disk error : host 3 channel 0 id 0 lun 0 return code = 8000002
Current sd08:21: sense key Data Protect
Additional sense indicates Write protected
I/O error: dev 08:21, sector 1
SCSI disk error : host 3 channel 0 id 0 lun 0 return code = 8000002
Current sd08:21: sense key Data Protect
Additional sense indicates Write protected
I/O error: dev 08:21, sector 1
* DUPs are designed to run only on a 32-bit environment. To run DUPs
on a pure 64-bit environment, use the Dell YUM repository.
* If you attach VMedia on a system with the iDRAC Firmware version 1.5,
some DUPs may fail to work. To resolve this issue, run the following
command:
racadm config -g cfgRacVirtual -o cfgLCDriveEnable 1
where cfgLCDriveEnable is an option implemented in iDRAC 1.5 with a
default of 0 (disabled)
NOTE: This command enables LCDrive from the iDRAC console or the OS.
If the LCDrive is not enabled, DUPs may not work.
After the DUP update is complete, to ensure the LCDrive is
invisible, run the following command: