###################################################################### DELL UPDATE PACKAGES README FOR LINUX ###################################################################### Version 7.2 Release Date: December 2012 This Readme contains updated information for your "Dell Update Packages for Linux Operating Systems User's Guide" and any other technical documentation included with the Dell Update Packages for Linux.
* PowerEdge Expandable RAID Controller (PERC) firmware * Software RAID Controller firmware * Baseboard Management Controller (BMC) firmware * SCSI Backplane (BP) firmware * SAS BP firmware * SAS Expander firmware * SSD firmware * SED firmware * SAS HDD Firmware * SAS Controller firmware * SEP firmware * PowerVault 100T firmware
* PowerVault 110T firmware * PowerVault MD1000 firmware * PowerVault MD1120 firmware * PowerVault MD1200 firmware * PowerVault MD1220 firmware * PowerVault RD1000 firmware * Power Supply firmware * Broadcom Network Adapter Firmware * Intel Network Adapter Firmware * QLogic Network Adapter Firmware * Emulex Network Adpater Firmware * OpenManage Server Administrator updates ######################################################################
CONTENTS ###################################################################### * CRITICALITY * MINIMUM REQUIREMENTS * UPDATE PACKAGES: SUPPORTED COMPONENTS * KNOWN ISSUES ###################################################################### CRITICALITY ###################################################################### 2 - Recommended It is recommended that you apply this update during your next scheduled update cycle.
The Update Packages support Dell systems running the following Linux operating systems: * Red Hat Enterprise Linux 5.8 x86 * Red Hat Enterprise Linux 5.8 x86_64 * Red Hat Enterprise Linux 6.3 server (64-bit) * SUSE Linux Enterprise Server 10 SP4 x86_64 * SUSE Linux Enterprise Server 11 SP2 x86_64 * VMware ESX Server version 4.1 Update 3 * Citrix Xen Server 6.
###################################################################### Update Packages currently do not support all system component types. Dell will continue to make Update Packages available on additional devices in future. This release of Update Packages supports updates to the devices listed in the following table.
PERC H710P Mini Blade,PERC H810 Adapter, PERC H710P Adapter,PERC H710 Mini Monolithic, PERC H310 Mini Monolithic,PERC H710 Adapter, PERC H710P Mini Monolithic,PERC H710 Mini Blade PERC H700 Adapter,PERC H700 Modular,PERC H800 Adapter, PERC H700 Integrated ---------------------------------------------------------------------BMC firmware BMC ---------------------------------------------------------------------SCSI BP firmware BP ---------------------------------------------------------------------SAS BP,
PowerVault 110T LTO4, PowerVault 110T SDLT320, PowerVault 110T DLT VS80, PowerVault 110T DLT VS160, PowerVault 110T SDLT ---------------------------------------------------------------------Removable disk drive PowerVault RD1000 backup firmware ###################################################################### KNOWN ISSUES ###################################################################### --------------------------------------------------------------------For all Dell Update Packages -----------
cannot open shared object file: No such file or directory", install the compatibility libraries from your Linux distribution. To install the compatibility libraries, use the following command: "rpm -ivh compat-libstdc++-33-3.2.3-47.3.i386.rpm" SLES 10 and SLES 11 (all service packs) uses "libstdc++-33-32bit-3.3.3-11.9.x86_64.rpm" * If Update Packages stop abruptly due to a power outage or abnormal termination, perform the following steps: 1. Remove the lock file. 2.
attempting to run a Dell Update Package from a USB flash drive under Linux, and are experiencing problems, remount the drive without the "-noexec" option, or copy the Dell Update Package to a drive mounted without the "-noexec" option. * Dell Update Packages do not require new refreshes of existing DUPs to be reinstalled since the firmware or driver payload does not change when the DUP is refreshed. A new DUP is available if changes have been made to the firmware or driver payload.
sdc: Write Protect is on SCSI disk error : host 3 channel 0 id 0 lun 0 return code = 8000002 Current sd08:21: sense key Data Protect Additional sense indicates Write protected I/O error: dev 08:21, sector 1 SCSI disk error : host 3 channel 0 id 0 lun 0 return code = 8000002 Current sd08:21: sense key Data Protect Additional sense indicates Write protected I/O error: dev 08:21, sector 1 Vendor: iDRAC Model: SECUPD Type: Direct-Access Rev: 0329 ANSI SCSI revision: 02 * DRAC5 updates are not supported on
where cfgLCDriveEnable is an option implemented in iDRAC 1.5 with a default of 0 (disabled) NOTE: This command enables LCDrive from the iDRAC console or the OS. If the LCDrive is not enabled, DUPs may not work. After the DUP update is complete, to ensure the LCDrive is invisible, run the following command: racadm config -g cfgRacVirtual -o cfgLCDriveEnable 0 * When you run USC-related DUPs with Citrix Xenserver 5.6.0-x, you need to set the virtual media in iDRAC to Detach.
displayed: "… mount: block device /dev/secmasupd-SECUPD is write-protected … /bin/cp: cannot create regular file …" * When you try to execute DUPs on a 64-bit RHEL operating system, it fails to execute since DUP is a 32-bit application. To work around this issue, manually install the following RPMs: glibc.i686 compat-libstdc++.i686 libstdc++.i686 zlib.i686 libxml2.
---------------------------------------------------------------------* Lifecycle controller updates require system services to be enabled. * For the first time, before you attempt to run Driver Package Diagnostics DUPs, execute the USC DUP. * Before running DUPs, ensure that there are no external devices mounted to /media or /tmp. * If the operating system is installed from "Operating System Deployment", select "Reboot and Exit" in the USC environment before booting to the operating system.
arbitration service of VMware ESX 4.1 and timeout occurs. The timeout occurs in the following instances: • When you start “DSM SA Shared Service” on the VMware ESX 4.1 managed node, it runs Inventory Collector. To work around this issue, uninstall Server Administrator or wait until the Inventory Collector completes execution before attempting to stop the “DSM SA Shared Service”. • When you manually try to run DUPs or the Inventory Collector on the VMware ESX 4.
12G BIOS ---------------------------------------------------------------------* BIOS updates require system services/Lifecycle controller to be enabled. * If the operating system is installed from "Operating System Deployment", select "Reboot and Exit" in the USC environment before booting to the operating system. This closes the USC session which is held for 18 hours.
the Dell Update Package for BIOS may fail. In this instance, you may attempt running the Dell Update Package immediately after reboot or after adding more memory. If this does not resolve the issue, update the BIOS using the diskette method. * If the above memory limitation occurs on VMware ESX Server, the problem is because the console operating system available memory is only 272 MB by default. Increase the console operating system memory to 800 MB temporarily and perform the firmware update.
dcd***: Unknown symbol put_user_size Ignore these messages because they do not refer to errors in BIOS update. ---------------------------------------------------------------------Dell Embedded Open Manage Server Administrator ---------------------------------------------------------------------- The Dell Update Package for Dell Embedded OpenManage Server Administrator can only be applied in a pre-operating system environment that uses ELI through the Dell OpenManage Deployment Toolkit (DTK).
---------------------------------------------------------------------- Before running the Dell (Emulex) Network firmware DUP ensure that Dell (Emulex) driver packages are installed on the system.
* Power Supply Unit firmware updates can be performed only on Life Cycle Controller enabled systems. ---------------------------------------------------------------------All PERC firmware and all SAS firmware ---------------------------------------------------------------------- * Do not run storage controller update packages if the controller is in use by other applications.
run "omconfig system webserver action=stop" To start the Server Administrator service, run "omconfig system webserver action=start" To stop the Server Administrator Storage Management Service, run "/etc/init.d/dataeng stop" To start the Server Administrator Storage Management Service, run "/etc/init.
* Stop all input/output to the PowerVault MD1000 before running the PowerVault MD1000 firmware update package. * WARNING: THE SERVER MUST BE REBOOTED AFTER UPDATING THE FIRMWARE ON MD1000 ENCLOSURES IN ORDER TO MAINTAIN ENCLOSURE MANAGEMENT. ACCESS TO THE ENCLOSURES WILL BE LOST IF THE SERVER IS NOT REBOOTED. * When prompted for reboot after the update, select "Yes".
The tape automation devices are as follows: 1. PowerVault 120T 2. PowerVault 122T 3. PowerVault 124T 4. PowerVault 128T 5. PowerVault 130T 6. PowerVault 132T 7. PowerVault 136T 8. PowerVault 160T 9. PowerVault ML6000 ###################################################################### Information in this document is subject to change without notice. (C) 2012 Dell Inc. All rights reserved. Reproduction of these materials in any manner whatsoever without the written permission of Dell Inc.
Linux® are registered trademarks of Red Hat, Inc.; SUSE® is a registered trademark of Novell, Inc. in the United States and other countries; VMware® is a registered trademark and ESX Server® is a trademark of VMware, Inc.; Citrix® and XenServer® are either trademarks or registered trademarks of Citrix Systems, Inc. in the United States and/or other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
physical act of transferring a copy.