Release Notes
Release Notes 13
For stopping the error
messages logged into the
log file, use one of the
following workarounds:
• Ensure a media is always
present in the SATA
CD/DVD drive. This
workaround avoids
exception messages being
sent to the log files.
• Reduce the level of event
logging by adding strings
in
/etc/vmware/logfilters
.
For more information, see
kb.vmware.com/kb/10044
99
.
A system running
ESX 4.x crashes
with a Purple
screen when the
SFP cable is
detached from the
Emulex CNA
card.
A system running ESX
4.x and installed with
the driver for the
Emulex CNA card (card
number OCE10102-FX-
D) crashes, if the SFP
cable connected to the
card is removed.
Upgrade the Emulex card
firmware revision to
2.103.269.2818 or the
higher version available.
ESX/ESXi
4.x
ESXi reports an
incorrect MAC
address for
PowerEdge
M-Series modular
systems enabled
with FlexAddress.
An incorrect MAC
address is set for ESXi
Management Network
Portgroup (vmk0) when
FlexAddress is enabled
on PowerEdge M-Series
modular systems.
To resolve the issue:
1
Run the following
command:
esxcfg-
advcfg -s 1
/Net/FollowHard
wareMac
in the
troubleshooting console
(Tech Support Mode).
2
Restart the server.
For more information, see
kb.vmware.com/kb/1031111.
ESXi 4.0.x
and 4.x
Issue Description Resolution Applies to