Release Notes
Release Notes 7
Known Issues and Resolutions
Issue Description Resolution Applies to
Installer screen is
misaligned during
ESX installation.
Screen resolution is
improper during ESX
installation.
This is a known issue. ESX 4.1
Update 2
BIOS Revision
string displays
incorrectly on
ESXi installation
failure screen.
BIOS Revision string
displays the vendor
name instead of the
BIOS revision, when
ESXi installation fails.
This is a known issue. ESXi 4.x
Power
Management
settings are
displayed as Not
supported and
Not applicable.
In systems with AMD
Opteron 6200 and AMD
Opteron 4200 series of
processors, Power
Management settings in
vCenter is displayed as
Not supported and Not
applicable.
This is a known issue. ESX/ESXi
4.1
Update 2
Errors related to
Equal Logic
Multipathing
Extension Module
(MEM)are seen.
The error message
EnumerateAssoci
ationsFault
is
seen when parameters
of Equallogic MEM are
changed or viewed from
ESX CLI command line
utility.
This is a known issue. To
resolve this issue:
1
Increase
ulimit
value to
1024 using the command
:
ulimit –n 1024
2
Change
provProcs
value
from 16 to 12 in
/etc/sfcb/sfcb.cfg
3
Restart
sfcbd
for the
changes to take effect
using the command:
/etc/init.d/sfc
bd-watchdog
restart
NOTE:
These settings are
not persistent across
reboots.
Dell
customized
VMware
ESXi 4.1
Update1
A05