Table 19. PowerEdge T350 PSU specifications
PSU Class Heat
dissip
ation
(maxi
mum)
Frequenc
y
Voltage AC DC Current
High line
200 - 240 V
Low line 100
- 120 V
450 W AC Bronze 1871
BTU/
hr
50/60 Hz 100240 V AC,
autoranging
450 W 450 W N/A 6.5 - 3.5 A
600 W AC Platinu
m
2250
BTU/
hr
50/60 Hz 100240 V AC,
autoranging
600 W 600 W N/A 7.1 - 3.6 A
600 W Mixed
Mode HVDC
N/A 2250
BTU/
hr
N/A
240 V N/A N/A 600 W 2.9 A
NOTE: This system is also designed to connect to the IT power systems with a phase-to-phase voltage not exceeding 240
V.
NOTE: Heat dissipation is calculated using the PSU wattage rating.
NOTE: When selecting or upgrading the system configuration, to ensure optimum power utilization, verify the system
power consumption with the Dell Energy Smart Solution Advisor available at Dell.com/ESSA.
Environmental specifications
NOTE:
For additional information about environmental certifications, refer to the Product Environmental Datasheet located
with the Documentation > Regulatory Information on www.dell.com/support/home.
Table 20. Operational climatic range category A2
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
1035°C (5095°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 80% RH with 21°C (69.8°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/300 m (1.8°F/984 Ft) above 900
m (2953 Ft)
Table 21. Operational climatic range category A4
Temperature Specifications
Allowable continuous operations
Temperature ranges for altitudes <= 900 m (<=
2953 ft)
545°C (41113°F) with no direct sunlight on the equipment
Humidity percent ranges (non-condensing at all
times)
8% RH with -12°C minimum dew point to 90% RH with 24°C (75.2°F)
maximum dew point
Operational altitude de-rating Maximum temperature is reduced by 1°C/125 m (33.8°F/410 Ft) above
900 m (2953 Ft)
38 Appendix A: Additional specifications