Service Manual

Table Of Contents
Troubleshooting 11
2 No memory modules
are detected.
If two or more memory modules are
installed, remove the modules (see
"Replacing or Adding a Memory
Module" on page 104), and then reinstall
one module and restart the computer. If
the computer starts normally, continue
to install additional memory modules
(one at a time) until you have identified
a faulty module or reinstalled all
modules without error.
If available, install working memory of
the same type into your computer (see
"Replacing or Adding a Memory
Module" on page 104).
If the problem persists, contact Dell (
see
"Contacting Dell" on page 137)
.
3 Possible system board
failure.
Contact Dell (see "Contacting Dell" on
page 137).
4 RAM Read/Write
failure.
Ensure that no special requirements for
memory module/connector placement
exist (see "Replacing or Adding a
Memory Module" on page 104).
Ensure that the memory you are using is
supported by your computer.
If the problem persists, contact Dell
(see
"Contacting Dell" on page 137).
5 Real time clock failure.
Possible battery or
system board failure.
Replace the battery (see "Coin-Cell
Battery" on page 117).
If the problem persists, contact Dell
(see
"Contacting Dell" on page 137).
6 Video BIOS Test
Failure.
Contact Dell (see "Contacting Dell" on
page 137).
Code (repetitive
short beeps)
Description Suggested Resolution