Reference Guide

whitelist-db cpsec modify
whitelist-db cpsec modify mac-address
cert-type switch-cert|factory-cert
description <description>
mode disable|enable
revoke-text <revoke-text>
state approved-ready-for-cert|certified-factory-cert
Description
Modify an existing entry in the campus AP whitelist.
Syntax
Parameter Description
mac-address <mac-
address>
MAC address of the AP you want to enter into the cpsec whitelist database.
cert-type
Identify the type of certificate to be used by the AP.
l switch-cert: AP is using a certificate signed by the controller.
l factory-cert: AP is using a factory-installed certificate. This option should only be
used for AP model types W-AP105 and W-AP120 series.
description
(Optional) Enter a brief description of the AP. If the description includes spaces, you
must enclose the description in quotation marks.
mode
Select disable to disable an APs entry in the campus AP whitelist. A disabled AP will
not be able to contact the controller via a secure channel. Select enable to reenable a
disabled AP.
revoke-text
If you disable an AP entry, the revoke-text parameter allows you to enter a brief text
string describing why the AP was revoked.
state
Select one of the following AP states:
l approved-ready-for-cert: AP has been approved state and is ready to receive a
certificate.
l certified-factory-cert: AP is certified and has a factory-installed certificate.
Example
The following command changes the certificate type, AP state and description of the AP with the MAC address
00:1E:37:CB:D4:52:
(host) (config) #whitelist-db cpsec modify mac-address 00:1E:37:CB:D4:52
cert-type switch-cert
state certified-factory-cert
description "An legacy AP model, apname AP-corp16"
Related Commands
Command Description Mode
show whitelist-db cpsec
Show the campus AP whitelist for the control plane feature. Enable mode
Dell PowerConnect W-Series ArubaOS 6.2 | Reference Guide whitelist-db cpsec modify | 1477