traffic-id <traffic-id>
Description
This command configures a TSM Report Request Profile.
Syntax
Parameter Description Range
Defaul-
t
<profile-name>
Name of this instance of the profile. The name must be 1-63
characters.
“defaul-
t
bin0-range <bin0-range>
This value is used to set the 'Bin 0 Range' field in the
Transmit Stream/Category Measurement Request frame.
Bin 0 Range indicates the delay range of the first bin (Bin 0)
of the Transmit Delay Histogram, expressed in units of TUs.
0- 255 6
clone <source>
Creates a copy of the Transmit Stream Measurement
Request Report Request Profile.
<source> is the name of an existing TSM Profile from which
parameter values are copied.
dur-mandatory
This parameter is used to set the "Duration Mandatory" bit of
the Measurement Request Mode field of the Transmit
Stream/Category Measurement Request frame.
Enabled
measure-duration <measure-
duration>
This parameter is used to set the Measurement Duration
field in the Transmit Stream/Category Measurement
Request frame. The Measurement Duration is set to the
duration of the requested measurement. It is expressed in
units of TUs. When the request mode for the Transmit
Stream/Category Measurement Request frame is set to
"triggered", the Measurement Duration field should be set to
0.
0- 65535 9776
no
Negates any configured parameter
num-repeats <num-repeats>
This parameter is used to set the "Number of Repetitions"
field in the Transmit Stream/Category Measurement
Request frame. The Number of Repetitions field contains
the requested number of repetitions for all the
Measurement Request elements in this frame. A value of
zero in the Number of Repetitions field indicates
Measurement Request elements are executed once without
repetition. A value of 65535 in the Number of Repetitions
field indicates Measurement Request elements are
repeated until the measurement is cancelled or
superseded.
0-65535 65535
random-interval <random-
interval>
This parameter is used to set the Randomization Interval
field in the Transmit Stream/Category Measurement
Request frame. The Randomization Interval is used to
specify the desired maximum random delay in the
measurement start time. It is expressed in units of TUs (Time
Units). When the request mode for the Transmit
Stream/Category Measurement Request frame is set to
"triggered", the Randomization Interval is not used and is set
0-65535 0