Reference Guide

Parameter Description Range Default
received within the EAP rate time interval to
trigger an alarm.
eap-rate-time-interval
Time, in seconds, during which the
configured number of EAP handshakes must
be received to trigger an alarm.
1-120
seconds
3 seconds
fata-jack-quiet-time
Time to wait, in seconds, after detecting a
FATA-Jack attack after which the check can
be resumed.
60-360000
seconds
900
seconds
invalid-address-combination-
quiet-time
Time to wait, in seconds, after detecting an
invalid address combination after which the
check can be resumed.
60-360000
seconds
900
seconds
malformed-association-request-
quiet-time
Time to wait, in seconds, after detecting a
malformed association request after which
the check can be resumed.
60-360000
seconds
900
seconds
malformed-auth-frame-quiet-time
Time to wait, in seconds, after detecting a
malformed authentication frame after which
the check can be resumed.
60-360000
seconds
900
seconds
malformed-htie-quiet-time
Time to wait, in seconds, after detecting a
malformed HT IE after which the check can
be resumed.
60-360000
seconds
900
seconds
malformed-large-duration-quiet-
time
Time to wait, in seconds, after detecting a
large duration for a frame after which the
check can be resumed.
60-360000
seconds
900
seconds
no
Negates any configured parameter.
omerta-quiet-time
Time to wait, in seconds, after detecting an
Omerta attack after which the check can be
resumed.
60-360000
seconds
900
seconds
omerta-threshold
The Disassociation packets received by a
station as a percentage of the number of
data packets sent, in an interval of 10
seconds.
1-100 10%
overflow-eapol-key-quiet-time
Time to wait, in seconds, after detecting a
overflow EAPOL key request after which the
check can be resumed.
60-360000
seconds
900
seconds
overflow-ie-quiet-time
Time to wait, in seconds, after detecting a
overflow IE after which the check can be
resumed.
60-360000
seconds
900
seconds
power-save-dos-min-frames
The minimum number of Power
Management OFF packets that are required
to be seen from a station, in intervals of 10
second, in order for the Power Save DoS
check to be done.
1-1000 120
power-save-dos-quiet-time
Time to wait, in seconds, after detecting a
Power Save DoS attack after which the
60-360000
seconds
900
seconds
Dell PowerConnect W-Series ArubaOS 6.2 | Reference Guide ids dos-profile | 285