Users Guide

Dell PowerConnect W-AirWave | User Guide Configuring and Using Device Groups in AMP | 77
11. To configure settings specific to Cisco WLC, locate the Cisco WLC section and adjust these settings as
required. Table 46 describes the settings and default values.
12. To configure Proxim/Avaya specific settings locate the Proxim/Avaya section and adjust these settings as
required. Table 47 describes the settings and default values.
13. To configure HP ProCurve specific settings, locate the HP ProCurve section and adjust these settings as
required. Table 48 describes the settings and default values.
Table 46 Cisco WLC Fields and Default Values
Setting Default Description
SNMP Version 2c Sets the version of SNMP used by AMP to communicate to WLC controllers.
CLI Communication Telnet Sets the protocol AMP uses to communicate with Cisco IOS devices. Selecting SSH
uses the secure shell for command line page (CLI) communication. Selecting Telnet
sends the data in clear text via Telnet.
NOTE: When configuring Cisco WLC controllers, refer to “Configuring Wireless Parameters for Cisco Controllers” on page93.
Table 47 Proxim/Avaya Fields and Default Values
Setting Default Description
SNMP Version 1 Sets the version of SNMP used by AMP to communicate to the AP.
Enable DNS
Client
No Enables the DNS client on the AP. Enabling the DNS client allows you to set some values on the
AP by hostname instead of IP address. If you select Yes for this setting, additional DNS fields
display.
Primary DNS
server
Blank Sets the IP address of the Primary DNS server.
Secondary DNS
server
Blank Sets the IP address of the Secondary DNS server.
Default DNS
domains
Blank Sets the default DNS domain used by the AP.
HTTP Server Port 80 Sets this port as the HTTP server port on all Proxim APs in the group.
Country Code United
States
Configures AMP to derive its time settings based on the country of location, as specified in this
field.
Table 48 HP ProCurve Fields and Default Values
Setting Default Description
SNMP Version 2c Sets the version of SNMP used by AMP to communicate to the AP.
ProCurve XL/ZWeSM CLI
Communication
Telnet Sets the protocol AMP uses to communicate with ProCurve XLWeSM devices. Selecting
SSH will use the secure shell for command line (CLI) communication. Selecting Telnet
will send the data in clear text via telnet.
Controller SNMP Version 2c Specifies the version of SNMP used by AMP to communicate to the controller.
NOTE: DST Start Month, Start Day, End Month, End Day, and DST Offset are only visible if Daylight Saving Time is enabled in the
NTP section of the Groups > Basic configuration page.