Figure 10: Offload WMS Database field in Groups > Basic
6. Select Save and Apply.
7. Select Save.
This will push a set of commands via SSH to all Alcatel-Lucent local switches. OV3600 must have read/write
access to the switches in order to push these commands.
This process will not reboot your switches.
If you do not follow the above steps, local switches will not be configured to populate statistics. This decreases
OV3600's capability to trend client signal information and to properly locate devices. See "AOS-W CLI" on page 37 for
information about how to utilize the AOS-W CLI to enable stats on Alcatel-Lucent infrastructure.
If your credentials are invalid or the changes are not applied to the switch, error messages will display on the
switch's APs/Devices > Monitor page under the Recent Events section. If the change fails, OV3600 does not
audit these setting (display mismatches) and you will need to apply to the switch by hand. See "AOS-W CLI" on
page 37 for detailed instructions.
These are the commands pushed by OV3600 while enabling WMS Offload. Do not enter these commands:
configure terminal
no mobility-manager <Active WMS IP Address>
wms
general collect-stats enable
stats-update-interval 120
show wms general
write mem
WMS Offload with OV3600
To offload WMS on the Alcatel-Lucentswitches using OV3600:
1. In OV3600 Setup> General, locate the Device Configuration section and enable or disable Allow WMS
Offload Configuration in Monitor-Only Mode.