Users Guide

365 | Using VisualRF Dell Networking W-AirWave 8.0 | User Guide
Importing and Exporting in VisualRF
Exporting a campus
To export a campus from VisualRF so you can import it into another AirWave, follow these steps:
1. Navigate back to the Network view.
2. Right-click the Campus icon.
3. Select Export. An object selection window appears.
4. Select the objects to export and select Export. A File Download window appears.
5. Select Save and save the zipped file to your local hard drive for importation to another AirWave.
At this point, you are ready to deploy a production AirWave and manage devices by importing your exported campus
and matching the access points to your plan.
Importing from CAD
The Floor Plan Upload Wizard (FUW) should inherit all pertinent information from your CAD file if you follow this
procedure:
1. Determine UNITS - all modern CAD versions (2001 and newer) support UNITS
2. Determine MEASURE - Legacy CAD versions (2000 and older) used a Imperial or Metric system.
l If UNITS are 0 or undefined, then the standard dictates defaulting to MEASURE value
l If MEASURE is 0 or undefined, then the standard dictates defaulting to English and inches
3. Find MODEL VIEW - If the drawing contains multiple views the FUW will default to the Model view
4. Determine Bounding Box - FUW will encompass all lines and symbols on the drawing and create a bounding box
which is generally smaller than entire drawing. It is based on the UNITS or MEASUREMENT above.
5. Convert to JPG - FUW will convert the bounding box area to a JPG file with a resolution of 4096 horizontal pixels
at 100% quality.
6. Start Web UI of FUW Step #1 - This is the cropping step.
This and all subsequent steps use the converted JPG file. The greater the floor plan dimensions, the less clarity the
background image provides.
Batch Importing CAD Files
This process provides the ability to automatically upload many CAD files and auto provision existing walls and access
points, and contains the following topics:
l "Requirements" on page 365
l "Pre Processing Steps" on page 366
l "Upload Processing Steps" on page 366
l "Post Processing Steps" on page 366
l "Sample Upload Instruction XML File" on page 366
l "Common Importation Problems" on page 367
Requirements
l Operating System: Client machine must be Windows XP, Windows Vista, or Windows 7
l Flash: Version 9 or later