Users Guide

Table Of Contents
Dell PowerConnect W-AirWave 7.5 | User Guide Using VisualRF | 305
2. Review the VisualRF > Floor Plans page to ensure server is keeping up.
Sample Upload Instruction XML File
<?xml version="1.0" encoding="ISO-8859-1"?>
<visualrf:site_batch xmlns:visualrf="http://www.airwave.com" xmlns:xsi="http://
www.w3.org/2001/XMLSchema-instance" version="1" origin="lower-left">
<floor name="1st Floor" number="43" building-name="Library" campus-
name="University">
<image filename="blueprint1.dwg"/>
<access-points>
<access-point name="ART.1.1" x="190.26" y="222.31"/>
<access-point name="ART.1.2" x="136.12" y="208.60"/>
<access-point name="ART.1.3" x="75.02" y="221.47"/>
<access-point name="ART.1.4" x="73.41" y="132.48"/>
<access-point name="ART.1.9" x="196.67" y="98.34"/>
<access-point name="ART.1.8" x="179.07" y="55.97"/>
<access-point name="ART.1.7" x="119.64" y="56.12"/>
<access-point name="ART.1.6" x="74.53" y="56.36"/>
<access-point name="ART.1.5" x="59.18" y="38.01"/>
</access-points>
</floor>
<floor name="2nd Floor" number="44" building-name="Library" campus-
name="University">
<image filename="blueprint2.dwg"/>
<access-points>
<access-point name="ART.2.12" x="196.31" y="92.19"/>
<access-point name="ART.2.11" x="204.82" y="55.78"/>
<access-point name="ART.2.10" x="133.08" y="55.81"/>
<access-point name="ART.2.9" x="73.79" y="55.78"/>
<access-point name="ART.2.8" x="73.72" y="104.26"/>
<access-point name="ART.2.7" x="73.91" y="134.88"/>
<access-point name="ART.2.6" x="73.83" y="162.72"/>
<access-point name="ART.2.5" x="73.82" y="183.61"/>
<access-point name="ART.2.4" x="63.74" y="125.48"/>
</access-points>
</floor>
</visualrf:site_batch>
Common Importation Problems
Improper or undefined UNITS or MEASURE
Text embedded into the Model view which causes an inconsistent bounding box
Large dimensions which cause grainy resolution upon zoom
Legacy CAD versions prior to Release 15 or AutoCAD 2000.
Importing from a Dell PowerConnect W-Series Controller
The instructions below will enable you to seamlessly migrate all building, campus, and floor plan information
previously entered into a Dell PowerConnect W-Series controller.
Pre-Conversion Checklist
Prior to importing floor plans, ensure that VisualRF's memory allocation is sufficient for the anticipated number
of floor plans.