Reference Guide

40 | Increasing Location Accuracy Dell PowerConnect W-AirWave 7.6 | Best Practices Guide
Figure 27: Typical Tag Deployment
Prerequisites
You will need the following information to monitor and manage your Dell PowerConnect W-Series infrastructure.
l Ensure AirWave server is already monitoring Dell PowerConnect W-Series infrastructure
l Ensure WMS Offload process is complete
l Ensure firewall configuration for port 5050 (default port) supports bidirectional UDP communication between
the AirWave server's IP address and each access point's IP address
Enable RTLS service on the AirWave server
To enable RTLS service on the AirWave server, follow these steps:
1. Navigate to AMP Setup > General and locate the AMP Additional Services section
2. Select Yes for the Enable RTLS Collector option.
3. A new section will automatically appear with the following settings:
n RTLS Port - the match controller default is 5050
n RTLS Username - match the SNMPv3 MMS username configured on controller
n RTLS Password - match the SNMPv3 MMS password configured on controller