Dell PowerConnect W-AirWave 7.4 | Configuration Guide Configuration Reference | 155
Local Config of SNMP Management
The Local Config component, introduced in AMP 7.2, is used for local configuration of Dell PowerConnect W-
Series controllers. Locally configured settings are not pushed to local controllers by master controllers.
SNMP trap settings for controllers are managed locally. Trap settings for the AP are managed by group or global
configuration in Profiles > AP > SNMP. Refer to “Profiles > AP > SNMP” on page75 if you want to manage
AP settings.
To configure SNMP trap settings on a controller, navigate to the Local Config > SNMP Management page.
Select Add to create a new SNMP Management profile, or click the pencil icon to edit an existing profile.
Table 83 describes the fields that appear in the Details page for this profile:
Rule Type bssid Select one of the following options from the drop-down menu. Your selection in this
field changes an ensuing field that must be completed, as follows:
bssid—Selecting this option displays the BSSID field below. Specify the BSSID
in text.
dhcp-option-77—Selecting this option displays the DHCP Option 77 field below.
Enter this information in text.
encryption-type—Selecting this option displays the Encryption Type field below,
in which you must select the encryption type from the drop-down menu. Select
open, static-wep, or another other encryption type from the drop-down menu.
essid—Selecting this option displays ESSID field below, in which you enter the
ESSID in text.
location—Selecting this option displays the Location field below, in which you
enter the location in text.
macaddr—Selecting this option displays the MAC Address field below, in which
you must enter the MAC address.
Operator contains Select the matching operator.
User Role/VLAN ap-role If you selected role for the Set Type field above, then select the specific user role
from this drop-down menu.
If you selected VLAN for the Set Type field above, then select the specific VLAN from
this drop-down menu.
Table 82 Security > User Rules > Add/Edit User Rules Fields and Descriptions (Continued)
Field Default Description
CAUTION: If you push configuration to a controller without having imported the contents of this profile, it will stop responding to
the AMP, because the default profile has no community strings.
Table 83 Local Config > SNMP Management Profile Settings
Field Description
General Settings
Folder Set the folder with which the profile is associated. The drop-down menu displays all
folders available for association with the profile.
Name Enter the name of the profile.
SNMP Settings
Community Strings Community strings used to authenticate requests for SNMP versions before version 3.
NOTE: This is needed only if using SNMP v2c and is not needed if using version 3.