Dell PowerConnect W AirWave 7.1 | User Guide Configuring and Using Device Groups in AWMS | 89
14. To configure Symbol or Intel-specific settings, locate the Symbol/Intel section and adjust these settings as
required. Table 48 describes the settings and default values of this section.
15. To configure settings specific to Del
l PowerConnect W, locate the Dell PowerConnect W section and adjust
these settings as required. Table 49 describes the settings and default
values of this section.
SNMP Version 2c Drop-down menu specifies the version of SNMP used by AWMS to communicate to the
AP.
Table 47 HP ProCurve 420 Fields and Default Values
Setting Default Description
Note: DST Start Month, Start Day, End Month and End Day are only visible if Daylight Saving Time is enabled in the NTP section of
the Groups > Basic configuration page.
Table 48 Symbol/Intel Fields and Default Values
Setting Default Description
SNMP Version 2c Drop-down menu specifies the version of SNMP used by AWMS to communicate to the
device.
Symbol/Intel Client
Inactivity Timeout
(3-60
0 min)
3 Sets the minutes of inactivity after which a client associated to an Intel or Symbol AP will
be considered "inactive." A lower value typically provides a more accurate representation
of current WLAN usage.
NOTE: For
other APs, AWMS has more precise methods to determine when inactive clients
are no longer associated to an AP.
Symbol Controller
CLI Communication
Tel net Select which connection type is to support the command-line interface (CLI) connection.
The options are Telnet and secure shell (SSH). This is supported for WS5100 and RFS7000
devices only.
Web Config
Interface
Yes Enables or disables the http/htt
ps configuration page for the Symbol 4131 and Intel 2011
devices.
Table 49 Dell PowerConnect W Fields and Default Values
Setting Default Description
SNMP Version 2c Drop-down menu specifies the version of SNMP used by AWMS to communicate to the AP.
Offload Dell
PowerConnect W
WMS data
base
No Configures commands previously documented in the Dell PowerConnect W AirWave Best
Practices Guide. See the current Best Practices guide for more information about this
feature. When enabled, this feature allows AWMS to display historical information for WLAN
switches.
Changing the setting to Ye
s pushes commands via SSH to all WLAN switches in Monitor Only
mode without rebooting the controller. The command can be pushed to controllers in manage
mode (also without rebooting the controller) if the Allow WMS Offload setting on the AWMS
configuration page is changed to Yes.
Dell PowerConnect
W GUI
Config
Yes Enables or disables AWMS support for the Dell PowerConnect W configuration interface.
This setting relates to the Device Setup > Dell PowerConnect W Configuration page and all
related operations. For additional information, refer to the Dell PowerConnect W
Configuration Guide.