Parameter Description
Values include: English, us, French, fr, German, de, Chinese Simplied, gb,
Chinese Traditional, b5, Japanese, jp, Korean, ko, Latin, la
load=yes/no species whether or not to load the language le. The
language le must end with the locale name and be placed under the
folder xen/locale in the le server.
For example, if you want to specify French and load the localized
messages, you must place a le named French.msg under the folder xen/
locale in the le server, and then add Locale=French load=yes in the INI
le
NOTE: You can use Local=fr instead of Locale=French.
IMPORTANT: For Chinese Simplied, Chinese Traditional,
Japanese, and Korean localization, a font le must also be
placed under the folder xen/font in the le server.
For example, if you want to specify the system language to be
Japanese, you must place a le named Japanese.msg under the
folder xen/locale in the le server, place a le named Japanese.fnt
under the folder xen/font in the le server, and then add
Locale=Japanese load=yes in the INI le.
If you are under a Dell maintenance contract, you can download .fnt
and .msg les from your My Downloads page in the Self-Service Center.
For more information, see "Technical Support".
If you are not under maintenance and wish to gain access to these les,
you must complete a product registration.
LocaleList=<value>
LocaleList — Species a list of locale, so that a user can switch the
system language as needed.
Be to place the required les, for example German.msg, Japanese.msg,
Japanese.fnt, and so on under the correct folders as described in the
Locale parameter description.
Lpdspool={0–50} Species the size of spool to buer all the data before sending them to
the LPD printer. The range of value is 0 to 10. It means 0 MB to 10 MB. If
the specied value is over the range, then it is set to 5. The range of value
is extended to 50.
In build 2.2_001 or after, the LPD data is spooled to a le in a ram disk
instead of a buer. So the value of the parameter will not be related to
the spool size as before. If Lpdspool=0, the function is disabled, otherwise
the function is enabled.
ManualOverride=[no, yes]
[Components={None, display, keyboard, mouse, timezone,
network, audio, printer, language, All}]
The parameter ManualOverride allows the end users to keep their
personalized settings. The default value is No.
If the value is set to No, personalized setting is not allowed.
If the value is set to Yes, the personalized settings are saved in the device
component which can be specied using the components option.
The parameter Components species the component that is allowed as a
personalized setting. Currently the options supported are None, display,
keyboard, mouse, timezone, network, audio, printer, language, all. The
default value is None.
Creating and Using xen.ini Files 199