Deployment Guide

Table 6. Connection Settings: wnos.ini files only (continued)
Parameter Description
encrypted password, you must set encrypt to yes.
For example: VncPassword=<encoded password>
encrypt=yes
If you are using a plain text password, you must set
encrypt to no. For example:
VncPassword=<plain text> encrypt=no
See also MaxVNCD in Connection Settings: wnos.ini files
only to enable VNC shadowing.
See also VNCPrompt in Connection Settings: wnos.ini
files, {username} INI, and $MAC INI Files to enable a VNC
shadowing prompt to a user.
WarnUnlinkDisabled={yes, no}
Default is no.
Yes/no option to disable the pop-up warning message when a
network has no link for an ICA/ RDP session.
WDAService=yes
[Priority ={WDM, CCM, WDM;CCM, CCM;WDM}]
[disableNotice={yes, no}]
[disableCancel={yes,
no}]
[noticeTime={0-255}]
[interval = {0-65535}]
[enableReminder={yes, no}]
WDA Service always runs in the background.
PriorityIf priority is available, WDA discovers the protocol
according to it.
There are only two protocols available now - WDM, and CCM.
For example, if priority=WDM; CCM, WDA tries to discover
WDM server and tries to check-in, and if it fails to check-in to
WDM server, it tries to check-in the device to CCM server.
disableNoticeIf option is set to yes, count down prompt
will not show when configuration from WDM is received.
Default is no.
disableCancelIf set to yes, there is no possibility to cancel
count down prompt for WDM (device is going to reboot).
Default is no.
noticeTimeIf this is set, then the time of countdown
prompt is changed to seconds. Default is 20 seconds.
Examples: WDAService=yes disableNotice=no
disableCancel=yes noticeTime=0. In this scenario, count down
prompt is displayed if WDM configuration is received, but you
are not allowed to cancel system reboot, and amount time of
count down prompt is set to default value (20 seconds).
intervalIf interval is available, WDA rediscovery is delayed
after check-in fails (both CCM and WDM fails). This delay is
changed to interval minutes. Default is 0. (WDA rediscovery
delay is 24 hours).
Example: WDAService=yes interval=30
WDA rediscovery delay is set as 30 minutes.
enableReminderIf enableReminder is set to yes, the
reboot warning window is displayed and the user has an option
to postpone the reboot. The default value is No.
Example: WDAService=yes enableReminder=yes
Whenever a reboot is required from Wyse Management Suite
agent, a warning dialog window is displayed. The user can
postpone the reboot for as many times set by the admin.
Parameters for wnos INI files only
41