Setup Guide

[smartcards={no, yes}]
[mapdisks={no, yes}]
[disablesound={no, yes, 2}]
[unmapusb={no, yes}]
[DisksReadOnly={no, yes}]
[MouseQueueTimer={0–99}]
[WyseVDA={no, yes}]
[WyseVDA_PortRange=startPort, endPort]
[UnmapClipboard={no, yes}]
[DefaultColor={0,1,2}]
[VUSB_DISKS={yes, no}]
[VUSB_AUDIO={yes, no}]
[VUSB_VIDEO={yes, no}]
[VUSB_PRINTER={yes, no}]
[FullScreen={no, yes}]
[Resolution={default, vga_resolution}]
[DisableResetVM={no, yes}]
[WyseVDAServerPort=serverPort]
[FontSmoothing={yes, no}]
[AutoConnect={yes, no}]
[MultiMonitor={yes, no}]
[EnableImprivataVC={yes,no}]
[Locale=LocaleID]
[SessionLogoTimeout=seconds]
[GroupSession={yes,no}]
smartcards
— Default is no. Yes/no option to use smartcards.
mapdisks — Default is no. Yes/no option to map disks.
disablesound — Default is no. Yes/no option to disable sound. If
value is set to 2, the sound at remote computer is disabled.
unmapusb — Default is no. Yes/no option to un-map USBs.
DisksReadOnly — Default is no. Yes/no option to mount mass
storage disks as read-only.
MouseQueueTimerSpecies the default queue timer of a
mouse event in an ICA or RDP session (in 1/100 of a second). It can
be used to adjust the bandwidth of a network.
WyseVDA — Default is no. Yes/no option to enable Virtual Desktop
Accelerator for all ICA and RDP sessions.
WyseVDA_PortRange — Sets the ThinOS VDA client port range.
The port range must follow these rules:
1 The port range is a list of start port and end port separated by
a semicolon (;) or a comma (,).
2 Both ports must be between 1 and 65535.
3 The end port must be greater than start port.
For example, WyseVDA_PortRange=3000,3010, the start port is
3000, the end port is 3010.
UnmapClipboard — Default is no. Yes/no option to disable
clipboard redirection for all sessions. For ICA and RDP, species if
redirecting the clipboard. This setting in wnos.ini will be saved into
nvram, if EnableLocal parameter is set to yes in wnos.ini.
DefaultColorSpecies the default color depth to use for the
session 0=256, 1=High color, 2=True Color.
VUSB_DISKS, VUSB_AUDIO, VUSB_VIDEO, and
VUSB_PRINTER — Default no. Species if these USB devices will
be redirected to the server using TCX Virtual USB or ICA or RDP
USB redirection. By default, these devices are set as local devices.
NOTE
: For example, if you want to use USB disks as a
network disk, you can set SessionCong=all
mapdisks=yes VUSB_DISKS=no.
If you want to use USB disks as server side device, you can
set SessionCong=all mapdisks=no VUSB_DISKS=yes. The
devices are displayed in device manager of the session.
FullScreen — Default is no. Species the default screen mode.
When using FullScreen in a Dual Screen mode, the session will be
displayed in Span mode
Resolution — Default is default. Species the session resolution.
For example, 640 x 480 and other supported resolutions.
Default will set the resolution to the native resolution of the
monitor. Setting the resolution to a value smaller than the native
resolution of the monitor, will allow the session in Windowed mode.
The resolution value cannot be higher than the native resolution.
DisableResetVM — Default is no. Set DisableResetVM=yes to
disable Reset VM function. As default, this function is controlled by
the server side is enabled including VMware View or Citrix PNA.
Parameters for wnos INI, {username} INI, and $MAC INI
les 83