Reference Guide

Parameter Description
ExpireTimeSpecies the signon expiration time. The range is 0
to 480 minutes. The default is 0 which means no expiration.
If the value is larger than 480, then 480 is set instead. If the value is
smaller than 0, then 0 is set instead.
After system signon or starting a connection, the expiration time
starts counting. Once the expiration time is reached, starting a
connection by clicking the icon, menu or connection manager, will
bring up a pop up message box to enter the password. Only if the
password is same as the original signon password, the session
starts.
If the terminal is locked and unlocked with the password, the signon
expiration time starts counting again.
UnlockRefresh — Default is yes. Yes/no option to species the
refresh action after unlocking the system in classic mode.
Yes — While unlocking, the system will refresh the PNA list to
verify the password.
No — Disables refresh.
SCShowCNName — Default is yes. Yes/no option to force the use
of the CN name of the certicate as the user name when using
smartcard signon. The default uses the UPN name as the user
name.
SCSecurePINEntry — Default is no. Yes/no option to enable
Secure PIN entry function for pkcs15 smart card with Cherry
keyboard.
AutoConnectTimeout— Default is 30 seconds.
This option sets the timeout for auto connect published
application. The range is 10 seconds to 300 seconds.
DisableEditDomain— The optional keyword DisableEditDomain, is
set to yes to stop typing in the domain box manually. Typing the
character @ or \ as in the format domain\user and user@domain in
the username box are not allowed.
AdGroupPreFix— The option AdGroupPreFix is only valid, when
you congure SignOn=NTLM. If the option is congured, then the
thin client veries the names of all AD groups to which a sign-on
user belongs, to get the rst group name so that its prex matches
adgrpnameprex, and load
adgroup/"the_whole_ad_group_name".ini, if the conguration le
exists, before loading the user specic INI.
For example, if the sign on user is user_111 in a domain, and the
user_111 belongs to group domain user and group tc_grp1_ad, the
option is congured as AdGroupPrex=tc_grp1. If the conguration
le adgroup/tc_grp1_ad.ini is available, it will be loaded.
ClearUserThe option keyword ClearUser, if set to yes, clears the
username when login fails, and if set to no, retains username
entered after login failure. The default value is no.
DisableSignoThe option keyword DisableSigno, if set to yes,
disables signo button from shutdown and connection manager
window. Also this parameter disables the logo button on
StoreFront desktop.
38
Parameters for wnos INI les only