Release Notes

Table Of Contents
NOTE: Every INI parameter is associated with a parent INI parameter. Use these INI parameters along with the
corresponding parent INI parameters.
Table 61. INI parameters
INI parameters Description
[enableEEE={0,1}] This parameter enables or disables ENERGYSTAR 8 on your ThinOS-based client. By
default, the value is set to 1.
[Microphone={yes, no}] This parameter enables or disables microphone devices on the Wyse 5470 All-in-One
Thin Client. The default value in BIOS is set to yes.
[InternalSpeaker={yes, no}] This parameter enables or disables internal speakers on the Wyse 5470 All-in-One Thin
Client. The default value in BIOS is set to yes.
[OneSignTimeout=0 to 30] This parameter enables you to set the timeout for the OneSign login window. The
value range is 0–30 s. By default, the value is set to 20 s. 0 means no timeout and the
OneSign login window stays forever.
[SkipEnter={yes, no}] This parameter enables or disables the ability to log in as an anonymous user without
pressing the Enter key.
[LimitCoredumpPartition={yes, no}] This parameter reduces the total number of saved coredumps by limiting the space
on Non-Volatile Random Access Memory (NVRAM). Enabling this option reduces the
user login time.
[EnableAWSREGCode={yes, no}] This option enables or disables the ability to change the registration code for
connecting to Amazon Workspaces.
For more information about the newly added INI parameters, see the Dell Wyse ThinOS 8.6 INI Reference Guide at
www.dell.com/support.
Fixed issues
Table 62. Fixed issues
Issue ID Description
THINOS-1485 Resolved the issue where black boxes are displayed in an ICA session when you are using Office
applications.
THINOS-1674 Resolved the issue where the session may disconnect abruptly.
THINOS-1705 Resolved the issue where the Shutdown dialog box stops responding when you click Sign off from
account. This issue is observed on Wyse 5070 and 5010 thin clients.
THINOS-1805 Resolved the issue that is observed when adding or removing SSIDs for thin clients using Wyse
Management Suite.
THINOS-1831 Resolved the issue where you cannot log in to a direct RDP connection when the authentication
server is Windows 2012.
THINOS-1840 Resolved the issue where the audio is distorted when you connect two headset devices. This issue is
observed on the Wyse 5060 Thin Client.
THINOS-1841 Resolved the issue where a certificate error is observed when you change groups using Wyse
Management Suite.
THINOS-1854 Resolved the issue where the thin client does not power on using smart card. This issue is observed
on the Wyse 5010 thin client.
THINOS-1855 Resolved the issue where the system log displays two displays even though you have connected a
single display. This issue is observed on the Wyse 3020 Thin Client.
THINOS-1856 Resolved the issue where black patches or objects are displayed on the screen when you drag a
published application window.
THINOS-1862 Resolved the issue where you cannot connect to the Azure RDP session from ThinOS.
104 ThinOS 8.6_303 and ThinOS Lite 2.6_303