Release Notes

Known Issues Workaround
changes to this field are not respected by the zero client firmware.
Instead, the IPv6 gateway is determined using IPv6 Router
Advertisement.
Zero client AWI cannot be accessed when touch monitor may lose
calibration in OSD is entered in the IPv6 Manual address field.
Use the On-Screen Display (OSD) to reconfigure the IPv6 address
settings.
Evoluent VerticalMouse 4 does not work when connected behind a
hub during active session.
Avoid plugging the device into a hub port while a session is active
or connect the device to a zero client root port. Alternatively,
disconnect and reconnect the session after plugging the mouse
into a zero client behind a hub.
Elo touch monitor may lose calibration in OSD after used in bridged
mode with certain Elo Multi-Touch drivers.
Use version 5.5.3 of the Elo multi-touch driver. This issue has not
been observed with this driver version.
Disconnecting one display resets preferred resolution override on all
displays.
When multiple displays have preferred resolution override applied
to them, disconnecting one display will clear the override for all
displays.
Gemalto IDCore 3020 smart cards is missing correct driver in
Windows 7.
Install the correct driver from a default Windows 7 installation:
From the zero client administrative web interface, bridge the
smart card reader.
Without the smart card inserted, log in to the virtual desktop
with username/password.
Insert the smart card. Windows 7 should recognize the smart
card and reader and automatically install the correct drivers.
Log off Windows to disconnect the session.
From the zero client administrative web interface, remove the
bridge configuration for the smart card reader.
Log in with the smart card. The smart card should be fully
accessible.
OneSign cannot authenticate after changing Session Connection
Type.
Restart the zero client.
After display is turned off, screen does not wake up by pushing zero
client button.
When the On-Screen Display (OSD) Screensaver timeout expires,
it will turn off the display after the end of a PCoIP session
brokered by a PCoIP Connection Manager. Clicking the zero
client’s physical button does not wake the display.
OSD cursor briefly stops responding to mouse input. The On-Screen Display (OSD) cursor stops responding to mouse
input for a few seconds after pressing the apply button on the
AWI USB permissions page, or while loading the AWI attached
devices page. It behaves as expected shortly after.
Switching between DVI and display port connectors may cause
screen to go blank on HP Z27i displays.
HP Z27i displays connected to a zero client’s display port
connectors may not show the remote desktop content when the
zero client starts a PCoIP session to a workstation access card,
and the card’s previous session was from a zero client with
displays attached to its DVI ports.
Temporary IPv6 addressing causes failure when connecting zero
clients to any soft host.
Zero clients cannot establish a connection to any soft host that
has temporary IPv6 addressing enabled.
Nessus warns on SNMP community name. Change the SNMP community name or disable SNMP.
Disconnecting a session with auto-reconnect enabled causes an
alert dialog.
With the auto-reconnect feature enabled, users may see an alert
dialog briefly on screen before the PCoIP session is reconnected.
The message shown is Unable to connect (0x1001). Please
contact your IT administrator. This message can be safely ignored.
8 Dell Wyse PCoIP Firmware Release 5.4.1 Release Notes