Setup Guide

Table 4. General Settings: wnos.ini files only (continued)
Parameter Description
For the parameter UpgradeOrder you can set a single entity
to upgrade or a list in order, (support valuebios and wtos)
Example:
If AutoLoad=1 and UpgradeOrder=biosOnly the BIOS is
upgraded.
If AutoLoad=1 and UpgradeOrder=bios, wtosThe BIOS is
upgraded first, and then the ThinOS firmware is upgraded.
If AutoLoad=1 and UpgradeOrder=wtos,biosThe thinOS
firmware is upgraded first, and then the BIOS is upgraded.
AutoLoad=1 UpgradeOrder=wtosOnly the ThinOS firmware
is upgraded.
AutoPower={yes, no}
or
Device=cmos AutoPower=(yes, no)
Default is no.
Yes/no option on how the system starts when the power is
first applied to the thin client.
If set to yes, then the system starts itself without waiting
for users to press the power button. In cases where power
was lost unexpectedly and if the thin client was shut down
properly before power was lost unexpectedly, when the power
is restored, the thin client will be powered. This setting is
useful in a kiosk environment.
Once an AutoPower statement is processed, it alters the
behavior of the thin client until a countermanding statement
is processed. The effect of an AutoPower=yes statement
continues even if the statement is removed from the INI file in
which it was found.
Use of the AutoPower option does not interfere with
performing a user directed shutdown.
WMSEnable={yes, no}
[Server=server_address[:port]
[GroupPrefix=<prefix>]
[GroupKey=<hashkey>]
[MQTTServer=<mqtt_address>[:<mqtt_port>]]
[AdvancedConfig={
no, yes}]
[Default={
no, yes}]
[Override={no, yes}]
[CAValidation=(yes, no)]
[Discover=(yes, no)]
[IgnoreMqtt=(yes, no)]
From ThinOS 8.4.1 release, these INI parameters are applicable
to Wyse 3040 thin client.
WMSEnable This parameter allows you to enable or
disable the Wyse Management Suite Agent. Default is no
Server Specifies an IP address or URL address for the
Wyse Management Suite server. Default protocol is HTTPS
if "http://" or "https://" is not available. Default port is
443. Once specified, it is saved in the non-volatile memory.
Example: WMSEnable=yes /Server=http://xxx:8080
GroupPrefix and GroupKey The options GroupPrefix and
GroupKey compose the Group Registration Key of the Wyse
Management Suite server. Once specified, it is saved in the
non-volatile memory.
NOTE:
The numbers before the dash on the Group Registration
key is the GroupPrefix value and the characters to the
right of the Group Registration Key is the GroupKey value.
NOTE: The length of GroupPrefix is fixed to four; the
length range of GroupKey is from eight to 31 characters.
MQTTServer Specifies a IP address or URL address for
the MQTT server and MQTT port after the : (colon). Once
specified, it is saved in the non-volatile memory.
Parameters for wnos INI files only
13