Setup Guide

Table 7. General Settings: wnos.ini files, {username} INI, and $MAC INI Files (continued)
Parameter
* Global overrides identically-named user
profile
** After sign off, user profile returns to
global value
Description
PictureLayout The optional parameter is used to specify the arrangement
on the desktop when pictures are displayed. For the tile selection, the image
is replicated across the desktop. For the center selection, the image is placed
at the center of the desktop without any image size change. For the stretch
selection, the image is either expanded or shrinked to fill the desktop. The
default value is stretch.
SleepThe optional parameter is used to specify the interval minutes to stop
soft screen saver and turn off monitor. After the specified minutes, since
software screen saver starts up, the software screen saver is stopped and
turns off the monitor until screen saver is off. The value range is 0180. The
value 0 is default which disables this function.
**ShutdownCount={0 to 60} (seconds)
or
**ShutdownCounter={0 to 60} (seconds)
ShutdownCount or ShutdownCounter Specifies the number of seconds
to count down before the shutdown sequence starts upon using the thin
client power button when there are active sessions.
The default value is 10, however, to commence shutdown immediately and
prevent the display of the countdown dialog box, set the value to 0.
ShutdownInfo={no, yes}
Yes/no option to display various information such as System Version, Terminal
Name, IP Address, and MAC Address in shutdown window.
SysinfoOntop=[yes,no]
This parameter enables the System Information window to be displayed at
the top in the Z-Order and overlaps on the nonmode switched full screen
session window.
TimeServer=server_list
[TimeFormat={24-hour format, 12-hour
format}]
[DateFormat={
yyyy/mm/dd, mm/dd/yyyy,
dd/mm/yyyy}]
[GetBiosDT={no, yes}]
[Timeout=time]
[Retry=number]
TimeServer Specifies the SNTP time servers to use for time retrieval. If a
time server is not defined, the client CMOS/ BIOS internal clock will be used
as a reference.
TimeFormat Default is 24-hour format. Specifies the time format to use.
DateFormat Default is yyyy/mm/dd. Specifies the date format to use.
NOTE:
The TimeFormat and DateFormat settings in a wnos.ini file will be saved
into NVRAM if EnableLocal=yes is set in the wnos.ini file.
GetBiosDT Default is no. Yes/no option to obtain time from BIOS/CMOS
when the timeserver is not available or cannot be contacted.
For Example:
TimeServer=time.nist.com \
TimeFormat=24-hour format \
DateFormat=mm/dd/yyyy
or
TimeServer=time.nist.gov \
TimeFormat=24-hour format \
DateFormat=mm/dd/yyyy
[Timeout=time]-This parameter enables the accurate time before the
certification verification process. Default is set to 0.
Parameters for wnos INI, {username} INI, and $MAC INI files
59