Install Guide

WDM Component Protocol and Corresponding
Ports
Port Function
DHCP Proxy and TFTP
Services and legacy support
for older WDM agents
UDP
44956
44957
Discover devices using subnet
directed broadcasts that have
older WDM Agents (5.0.0.x
and earlier) installed.
TCP 44955 Discover devices using IP
Range Walking. Upgrade
devices that have an older
WDM Agent (5.0.0.x and
earlier) installed.
ThreadX 4.x Manager Service TCP
9880
50000
Communicate with ThreadX
4.x devices.
ThreadX 5.x Manager Service TCP
49159
5172
Communicate with ThreadX
5.x devices.
NOTE: Both the
communication ports
has to be added to
rewall Inbound rules. If
required, 49159 port
number can be
customized. The default
port 49159 is
customized, this needs
to be manually added.
GUID-0A235F63-E857-4466-B578-235ACE4E9AB3
Requirements for Managing PCoIP Devices
PCoIP devices that run the ThreadX rmware require a DNS Service Location (SRV) resource record to perform the following
actions:
Partial Check-In (heartbeat) — The device performs a heartbeat check-in every hour.
Firmware Download Completion Status
The rmware upload is initiated by the server and the download completion is initiated by the device using the DNS SRV record.
ThreadX 4.x:
Congure FTP if you intend to use the rmware upgrade feature for PCoIP (ThreadX 4.x) devices. You must enable this in the
Software Repository. For more information on enabling FTP in the Software Repository, see the Dell Wyse Device Manager
Administrator’s Guide.
ThreadX 5.x:
Congure CIFS if you intend to use the rmware upgrade feature for PCoIP (ThreadX 5.x) devices. You must enable this in the
Software Repository. For more information on enabling CIFS in the Software Repository, see the Dell Wyse Device Manager
Administrator’s Guide
.
14