Installation and Service Manual

Table Of Contents
System diagnostics and indicator codes
This section describes the diagnostic indicators on the system front panel that displays the system status during system startup.
Topics:
Status LED indicators
System health and system ID indicator codes
iDRAC Quick Sync 2 indicator codes
iDRAC Direct LED indicator codes
LCD panel
NIC indicator codes
Power supply unit indicator codes
Drive indicator codes
Using system diagnostics
Status LED indicators
NOTE: The indicators display solid amber if any error occurs.
Figure 180. Status LED indicators
Table 46. Status LED indicators and descriptions
Icon Description Condition Corrective action
Drive indicator The indicator turns solid amber if
there is a drive error.
Check the System Event Log to determine if the
drive has an error.
Run the appropriate Online Diagnostics test.
Restart the system and run embedded
diagnostics (ePSA).
If the drives are configured in a RAID array,
restart the system, and enter the host adapter
configuration utility program.
Temperature
indicator
The indicator turns solid amber if
the system experiences a thermal
error (for example, the ambient
temperature is out of range or
there is a fan failure).
Ensure that none of the following conditions exist:
A cooling fan has been removed or has failed.
System cover, air shrouds, or back filler bracket
has been removed.
Ambient temperature is too high.
External airflow is obstructed.
If the problem persists, see the Getting help section.
Electrical
indicator
The indicator turns solid amber
if the system experiences an
electrical error (for example,
voltage out of range, or a failed
power supply unit (PSU) or voltage
regulator).
Check the System Event Log or system messages
for the specific issue. If it is due to a problem with
the PSU, check the LED on the PSU. Reseat the
PSU.
7
174 System diagnostics and indicator codes