Table 47. Thermal restriction matrix
Drive
Configuratio
n
Processo
r
Fans CPU
TDP
Fan
redundan
cy
CPU HSK GPU support TBU
suppo
rt
CPU blank Fan blank Note GPU riser
configurati
on
TDP>150
W
TDP<=15
0 W
GPU<=7
5 W
GPU>7
5 W
8 x 3.5 1 STD
x3
<=185 No HPR HSK STD HSK No No No Yes Yes at Fan
2 location
Fan 1/3/4 Riser 0, 1
1 STD
x6
<=220 Yes No No No Yes Fan 1/3/4/5/7/8 Riser 0, 1
1 HPR
x3
<=220 No Yes No No Yes Fan 1/3/4 No
1 HPR
x5*
<=220 Yes Yes/No No Yes Yes Fan 1/3/4/7/8
(GPU riser 1 and
2 not supported)
No
1 HPR
x6
<=220 Yes Yes Yes No Yes Fan 1/3/4/5/7/8 Yes
2 STD
x4
<=185 No No No No No No NA Riser 0, 1
2 STD
x8
<=220 Yes No No No No NA Riser 0, 1
2 HPR
x4
<=220 No Yes No No No NA No
2 HPR
x7*
<=220 Yes Yes/No No Yes No Fan
1/2/3/4/6/7/8
NOTE: GPU
riser 1 and 2
not
supported
No
2 HPR
x8
<=220 Yes Yes Yes No No NA Yes
8 x 2.5
16 x 2.5
24 x 2.5
1 or 2 STD
x4
<=185 No HPR HSK STD HSK No No No Yes for 1
processor
No NA Riser 0, 1
1 or 2 STD
x8
<=220 Yes No No No NA Riser 0, 1
1 or 2 HPR
x4
<=220 No Yes No No NA No
1 or 2 HPR
x7*
<=220 Yes Yes/No No Yes Fan
1/2/3/4/6/7/8
No
Appendix A. Additional specifications 57