Setup Guide

Environmental
Operating 20% to 80% (noncondensing) at a maximum wet
bulb temperature of 29 °C (84.2 °F)
Storage 5% to 95% at a maximum wet bulb temperature of
38 °C (100.4 °F)
Maximum Vibration
Operating 0.26 G
rms
at 5 Hz to 350 Hz (all operation
orientations)
Storage 1.87 G
rms
at 10 Hz to 500 Hz for 15 min (all six sides
tested)
Maximum Shock
Operating One shock pulse in the positive z-axis (one pulse on
each side of the system) of 31 G for 2.6 ms in all
operational orientations.
Storage Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 71 G for up to 2 ms.
Six consecutively executed shock pulses in the
positive and negative x, y, and z axes (one pulse on
each side of the system) of 32 G faired square wave
pulse with velocity change at 270 inches/second
(685 centimeters/second)
Altitude
Operating –15.2 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 ft, the
maximum operating temperature is derated
1ºF/550 ft.
Storage
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne Contaminant Level
Class
G1 as defined by ISA-S71.04-1985
8