Instructions / Assembly

SET THE SCALE
Set the scale for #1 Wood, #2 Plaster/Concrete reference
scale, or #3 Gypsum.
hTo change the scale, press the scale button
#. The meter
will display the current scale for one second.
hTo scroll forward through the scales hold the scale button
# while the current scale is displayed and scroll to the
scale desired.
hTo scroll backward through the scales, press and hold the
set-point button
$ within one second of pressing and
releasing the scale button
#. Continue to hold the set-point
button
$ and the scale number will decrease.
hWhen scrolling in either direction, release the button to
stop at your desired scale.
Changing the scale will automatically reset the set-point
value to the default setting for that particular scale. Default
settings are as follows:
#1 Wood Scale - 15%
#2 Plaster/Concrete Reference Scale - 85
#3 Gypsum Scale - 1%
CHANGE THE SET-POINT
hTo change the set-point value press the set-point button
$. The meter will display the current set-point value for
the scale you have chosen for one second.
hTo scroll forward to a higher value for that scale hold the
set-point button
$ while the current set-point is displayed
and scroll to the set-point value desired.
hTo scroll backward through the set-point values, press and
hold the scale button
# within one second of pressing and
releasing the set-point button
$.
hContinue to hold the scale button
# and the set-point
value will decrease.
hWhen scrolling in either direction, release the button to
stop at your desired set-point.
4