C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 2 C-2000 v2.0, 2.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 3
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 4 TABLE OF CONTENTS 2 C-2000 Features 3 Key Functions 3 Check Calibration 4 Set the Scale 4 To Change the Set-Point 5 Information About Your Readings 5 To Check the Accumulated Readings 6 To Reset Meter 6 Applications 9 Temperature Correction 9 Care Of Your Meter 10 Service for Your Meter 11 Warranty
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 5 DELMHORST C-2000 # ! Read Key Set-Point Key @ Calibration Check Key $ Scale Key C-2000 FEATURES hDesigned primarily to check the moisture content (%MC) in lint cotton and seed cotton. Versions 2.0 and higher include scales for viscose rayon and wool. hResistance technology recognized around the world as the most accurate method for measuring moisture.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 6 KEY FUNCTIONS ! Read: Reads the % MC value. @ Check: Checks the meter calibration. Displays the average of up to 100 accumulated readings; displays the highest stored reading; erases the readings from memory. # Set-Point: Displays the current set-point. Also acts as an arrow (scroll) key to increase the set-point value in 1% increments. A buzzer will alert you if the meter reads higher than the selected %MC value.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 7 A hard Reset is required if, after changing the battery, the display is frozen. This is sometimes caused by the interruption of contact between the battery and the battery lead wire. Resolve this as follows: Disconnect the battery. Press and hold the Read key for 15 seconds. Press and hold the Check key for 15 seconds. Release the Check key.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 8 INFORMATION ABOUT YOUR READINGS The meter will accumulate up to 100 readings. After all 100 readings are “stored” it will not add new readings until the memory has been cleared. It will also continue to display the average of all 100 readings as a reminder that the memory is full. hTo add a reading to the sum of all the previously stored readings, release the read key ! within 2 seconds.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 9 hTo keep the accumulated readings in memory release the calibration check key @ before the total cycle time is complete. hTo erase readings, hold the calibration check key @ for more than five seconds. The total, average and highest readings will be displayed as above, followed by a zero to indicate all readings have been erased. TO RESET METER hPress and release the calibration check key @.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 10 Readings below 6% seed cotton will be displayed as a negative number. Readings above 20% seed cotton will be displayed as a flashing “20.0%”. Both the underrange and the overrange readings should be disregarded. They will not be added to the accumulated readings or used in calculation of the average or highest reading. Tests made on seed cotton may not be as accurate as those made on lint cotton.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 11 Testing Baled Cotton hAttach the #30-E/C Electrode to the connector on top of the meter. hSlide the plastic spacer over the #491 contact pins from the bottom of the pins, mount the pins in the chucks and tighten the set screws. (The #491 contact pins are not inserted into the chucks for shipping purposes). hSet the Scale to #1 Lint cotton and select a set point. hInsert the electrode pins into the bale and press the read key !.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 12 Temperature Correction The basic calibration assumes the cotton temperature to be 70°F. For best accuracy, apply a temperature correction if the cotton temperature is outside the range of 60°F to 80°F. Make a correction of approximately 1.0% for every 20° F. The meter will read higher than the actual moisture content as cotton temperature increases, and will read lower as cotton temperature decreases.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 13 SERVICE FOR YOUR METER If your meter is not working properly, replace the battery with a new one and check the calibration. If this does not resolve the problem, go to www.delmhorst.com and follow the instructions under the Product Support tab. If you require further assistance please call 877-DELMHORST (335-6467) or 973-334-2557.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 14 WARRANTY Delmhorst Instrument Co., referred to hereafter as Delmhorst, guarantees its C-2000 meter for one year from date of purchase and any optional electrodes against defects in material or workmanship for 90 days. If, within the warranty period of the C-2000, you find any defect in material or workmanship return the meter following the instructions in the “Service for Your Meter” section.
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 15 NOTES
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 16 NOTES
C-2000 manual_2013-Revs_FX-2000 owners manual 1/25/13 11:17 AM Page 1 For 65 years Delmhorst Instrument has been the leading manufacturer of high quality, USmade moisture meters and thermohygrometers. Today we offer a wide range of meters for applications including water damage restoration, construction, flooring, lumber/woodworking, paper, and agriculture. . WHEN ACCURACY IS THE POINT ® TM 51 Indian Lane East Towaco, NJ 07082 (877)-DELMHORST (3 3 5 - 6 4 6 7 ) www.delmhorst.com info@delmhorst.