Specifications
10
GAS SUPPLY:
■ The connection must be performed by an authorised person according to the rel-
evant standards.
■ Before connecting the appliance to the gas main, mount the brass conical adap-
tor onto the gas inlet pipe, upon which the gasket has been placed (figures 1.14a-
1.14b).
Conical adaptor and gasket are supplied with the appliance (packed with con-
version kit for use with Natural gas or Universal LPG).
■ This appliance is suitable for use with Natural Gas or Universal LPG. (Check the
“gas type” sticker attached to the appliance).
■ For Natural Gas models the gas supply is connected to the pressure regulator
which is supplied with the appliance (fig. 1.14b). Adjust the regulator to obtain a
test point pressure of 1 kPa with both of the triple ring burners operating at the
maximum.
■ For Universal LPG models the gas supply is connected to the test point adaptor
which is supplied with the appliance (fig. 1.14a) and ensure that the supply pres-
sure is regulated to 2.75 kPa.
■ The connection must be made at the rear of appliance. If the connection pipe
cross the cooker, it must be positioned under the cooker rear protection (fig.
1.16).
■
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig.
1.15)
Figure 1.14b
Gas connection for
NATURAL GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adap-
tor
(Thread tight: use
suitable seal)
Gas regulator
Test
point
Gas connection for
UNIVERSAL LPG
Figure 1.14a
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Test
point
Figure 1.15
INSTALLATION










