GAS SUPPLY:
The connection must be performed by an authorised person according to the rel-
evant standards.
Before connecting the appliance to the gas main, mount the brass conical adap-
tor onto the gas inlet pipe, upon which the gasket has been placed (figures 1.14a-
1.14b).
Conical adaptor and gasket are supplied with the appliance (packed with con-
version kit for use with Natural gas or Universal LPG).
This appliance is suitable for use with Natural Gas or Universal LPG. (Check the
“gas type” sticker attached to the appliance).
For Natural Gas models the gas supply is connected to the pressure regulator
which is supplied with the appliance (fig. 1.14b). Adjust the regulator to obtain a
test point pressure of 1 kPa with both of the triple ring burners operating at the
maximum.
For Universal LPG models the gas supply is connected to the test point adaptor
which is supplied with the appliance (fig. 1.14a) and ensure that the supply pres-
sure is regulated to 2.75 kPa.
The connection must be made at the rear of appliance. If the connection pipe
cross the cooker, it must be positioned under the cooker rear protection (fig.
1.16).
IMPORTANT: Use two spanners to tighten or loosen the connecting pipe (fig.
1.15)
Figure 1.14b
Gas connection for
NATURAL GAS
Gas inlet pipe
Nipple
Gasket
Brass conical adap-
tor
(Thread tight: use
suitable seal)
Gas regulator
Test
point
Gas connection for
UNIVERSAL LPG
Figure 1.14a
Gas inlet pipe
Nipple
Gasket
Brass conical adaptor
(Thread tight: use
suitable seal)
Test point adaptor
Test
point