CONNECTING THE FEEDER
CABLE
To connect the feeder cable to the cooker
it is necessary to:
Remove the 4 screws that hold
shield A behind the cooker.
Open completely the cable clamp D.
Position the U bolts onto terminal
block B (fig. 1.1) according to the
diagrams in figs. 1.2a - 1.2b.
Insert the feeder cable into the cable
save C. The supply cable must be
of a suitable size for the current
requirements of the appliance; see
the section “Feeder cable section”.
Connect the phase and earth cables
to terminal B according to figures
1.2a - 1.2b.
Pull the feeder cable and block it
with the cable clamp D
Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
Figure 1.2b
FEEDER CABLE SECTION
type “H05RR-F”
230-240 V 3 x 4 mm
2
(**)
230 -240 V3 4 x 2,5 mm
2
(**)
400 -415 V 3N 5 x 2,5 mm
2
(**)
400 -415 V 2N 4 x 2,5 mm
2
(**)
(**) – Connection with wall box connection
– Diversity factor applied
INSTALLATION
230-240 V ~
23451
N(L2)
PE
L1
230 V 3 - 240 V 3 ~
23451
PE
L1 L2 L3
400 V 3N - 415 V 3N ~
23451
PE
L1 L2 L3 N
400 V 2N - 415 V 2N ~
23451
PE
L1 L2 N