Installation and Operation Guide
11
REPLACING THE POWER SUPPLY CABLE
Important! This appliance must be connected to the electricity supply only by an
authorised person.
To connect the supply cable:
■ Unhook the terminal board cover by inserting a screwdriver into the two hooks “A” (g. 6).
■ Unscrew the screw “D” and open completely the cable clamp “E” (g. 7).
■ Connect the phase, neutral and earth wires to terminal board “G” according to the
diagram in g. 8.
■ Strain the feeder cable and block it with cable clamp “E” (by screwing screw “D”).
■ Close the terminal block cover (check the two hooks “A” are correctly hooked).
N.B. The earth conductor must be left about 3 cm longer than the others.
IMPORTANT: To connect the power supply cable DO NOT unscrew the screws xing
the cover plate behind the terminal block.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac 3050 W (13.26 A)
FEEDER CABLE SECTION
TYPE H05RR-F
3 x 1,5 mm
2
(*) (**)
(*) Connection possible with plug and outlet
(**) Connection with wall box connection.
Figure 7
Figure 6
Figure 8
1
2
3
5
4
N
L2
PE
L1
G
D
E
PE
N
L
220-240 V ac
A