Operating instructions

35
Descriptions and illustrations in this booklet are given as simply indicative. The manufacturer reserves the right,
considering the characteristics of the models described here, at any time and without notice, to make eventual
necessary modifications for their construction or for commercial needs.
Fig. 9.1
D
B
PE
A
N
L
230 V
PEN
L
1
(L2)
Fig. 9.2
PE Earth
N Neutral
L Live
The connection of the appliance to earth is mandatory.
The manufacturer declines all responsibility for any inconvenience resulting from
not observing this condition.
Connecting the mains cable
To connect the supply cable:
- Remove the screws securing the cover “A” on the rear of the cooker (fig. 9.1).
- Feed the supply cable through the cable clamp “D”. The supply cable must be of a suitable
size for the current requirements of the appliance; see the section “Feeder cable section”
(fig. 9.1).
- Connect the wires to the terminal block “B” as shown in the diagram in figure 9.2; or connect
the phase wires to the terminal block “B” and the earth wire to the terminal PE as shown in
figure 9.1.
- Take up any slack in the cable and secure with the cable clamp “D”.
- Replace the cover “A”.
N.B. The earth conductor must be left about 3 cm longer than the others.
Feeder cable section
type H05RR-F
230 V 3 x 2,5 mm
2