Operating instructions

28
Installation to LP Gas
This appliance must only be connected to LPG after an LPG conversion kit has been fitted,
(see pages from 29 to 31).
When operating on Butane gas a supply pressure of 28-30 mbar is required.
When using Propane gas a supply pressure of 37 mbar is required.
The installation must conform to the relevant British Standards.
Warning: Only a qualified gas engineer, also with technical knowledge of electricity should
install the cooker.
He should observe the Regulations and Codes of Practice governing such installation of gas
cookers.
Note: It is recommended that the gas connection to the cooker is installed with a
flexible connecting tube made to BS 5386.
Gas connection
The gas supply must be connected to the gas inlet which is located at the left or the right
hand rear of the appliance (see figure 8.1).
The pipe do not cross the cooker.
To screw the connecting tube operate with two spanners (see fig. 8.2).
The unused end inlet pipe must be closed with the plug interposing the gasket.
After connecting to the mains, check that the coupling are correctly sealed, using
soapy solution, but never a flame.
Plug
Fig. 8.1
Fig. 8.2