9 Electrical installation
32
Connecting feeder cable
To connect the feeder cable to the cooker
it is necessary to:
– Remove the screw that hold shield “A”
behind the cooker (fig. 9.1).
– Insert the feeder cable of the suitable
section (as described in the next chap-
ter) into the cable clamp “D”.
– Connect the phase and earth cables to
the terminal block “B” according to the
diagram in figure 9.2.
– Pull the feeder cable and block it with
cable clamp “D”.
– Re-mount shield “A”.
Fig. 9.1
D
B
A
230 V
PEN
L
1
(L2)
Fig. 9.2
Feeder cable section
type H05RR-F
230 V 3 x 1,5 mm
2
PE
The appliance must be connected to the electrical network verifying above all that the volt-
age corresponds to the value indicated on the specifications plate and that the cables sec-
tion of the electrical plant can bear the load which is also indicated on the plate.
The cooker can be connected directly to the mains placing an omnipolar switch with mini-
mum opening between the contacts of 3 mm between the appliance and the mains.
The power supply cable must not touch the hot parts and must be positioned so that it
does not exceed 75°C at any point.
Once the cooker has been installed, the switch or socket must always be accessible.
Before effecting any intervention on the electrical parts the appliance must be dis-
connected from the network.
WARNING!
ELECTRICITY CAN BE EXTREMELY DANGEROUS.
THIS APPLIANCE MUST BE EARTHED.