Operation Manual
13
EN
Introduction
Installing the appliance
Attention!
The following safety measures must be complied with when
installing the appliance:
• Theappliancecould bedamaged bythe penetrationof
water.
Donotpositiontheapplianceneartowatertapsorsinks.
• Theappliancecouldbedamagedifthewateritcontains
freezes.Donotinstalltheapplianceinaroomwherethe
temperature can fall below freezing point.
• Positionthepowersupplycableinawaythatitcannotbe
damaged by sharp edges or by contact with hot surfaces.
Connecting the appliance
Attention!
Make sure that the electric mains voltage corresponds with
that indicated on the rating plate on the base of the appliance.
Only connect the appliance to a correctly installed socket with
a minimum rating of 10A and correctly earthed.
In the case of incompatibility between the socket and the
plug on the appliance, have the plug replaced by a qualied
technician.
• The power supply cable on this appliance must never
be replaced by the user as special tools are needed for
this operation. Contact an After-Sales Centre authorised
by the manufacturer if the cable is damaged or must
be replaced, in order to avoid all risks. Please refer to
enclosed guarantee leaet for details.
Filling the water tank
1. Open the water tank lid (g. 1) and then lift the tank to
remove it (g. 2).
2. FillthetankwithfreshwaterbutdonotpassMAXlevel
(g.3).Re-positionthetankbypressingitlightlyinaway
to open the valve situated on the base of the tank itself.
3. Alternatively, do not remove the tank, just ll it by pouring
in water from a jug, be careful of splashes
Attention!
Donotoperatetheappliancewithoutwaterinthetankand
always ll it when the water is a few centimetres from the
bottom.
Please Note: it is normal to nd water in the
compartmentunderthetank;dryusingacleansponge.
Description
A Selector dial
B Steam position
C “OFF” position
D Onindicatorlight
E OK indicator light
F Coee- hot water delivery position
G Steam dial
H Water tank
I Watertanklid
J Filter compartment
K Power supply cable
L Coeetamper
M Driptray
N Boiler outlet
O Steam or hot water tube
P Cappuccino nozzle
Q Filter holder
R Filter
S Measure
Technical date
Mainsvoltage: 220-240V
˜
50/60Hz
Absorbed power: 1100W
Dimensions(LxHxD): 195x285x240(330)mm
Pressure: 15 bar
Watertankcapacity: 1L
Cable lenght: 1,2 m
Weight: 3 kg