Instruction Manual
25
TROUBLESHOOTING
Below is a list of some of the possible malfunctions.
If the problem cannot be resolved as described, contact Customer Services.
PROBLEM POSSIBLE CAUSE SOLUTION
The coee is not hot
The cups were not preheated. • IfEnergySavingisnotactive,leavethecupsonthe
cup warmer for at least 20 minutes for them to warm
up.
• Warmthecupsbyrinsingthemwithhotwater
(using the hot water function).
The infuser has cooled down because 2/3 minutes have
elapsed since the last coee was made.
Before making the coee, heat the infuser by performing a
rinse cycle (see the section “Tips for a hotter coee”).
A low coee temperature is set. Set a higher coee temperature in the menu.
The coee is not creamy
enough.
The coee is ground too coarsely. Turn the grinding adjustment dial one click counter clockwi-
se towards “1” while the coee mill is in operation (g. 11).
Continue one click at a time until coee delivery is satisfac-
tory. The eect is only visible after delivering 2 coees.
Wrong type of coee Use a type of coee for espresso coee machines.
The coee is delivered too
slowly or a drop at a time.
The coee is ground too nely. Turn the grinding adjustment dial one click clockwise to-
wards “7” while the coee mill is in operation (g. 11). Con-
tinue one click at a time until coee delivery is satisfactory.
The eect is only visible after delivering 2 coees.
The coee does not come out
of the spouts, but from around
the service door.
The holes in the spouts are clogged with dry coee dust. Clean the spouts with a toothpick, sponge or hard bristled
kitchen brush.
The coee guide inside the service door is blocked and
cannot swing.
Thoroughly clean the coee guide, particularly near the
hinges.
The coee is delivered too
quickly.
The coee is ground too coarsely. Turn the grinding adjustment dial one click counter clockwi-
se towards “1” while the coee mill is in operation (g.
11). Avoid turning the grinding adjustment dial excessively
otherwise when you select two cups, the coee may be de-
livered a drop at a time.
Coee does not come out of
one of the spouts.
The spouts are blocked. Clean the spouts with a toothpick
GENERAL ALARM
The inside of the appliance is very dirty. Clean the inside of the appliance thoroughly, as described in
the section “Cleaning and maintenance”.
If the message is still displayed after cleaning, contact
customer services.
EMPTY CIRCUIT
FILL CIRCUIT
alternating with...
Water delivery
PRESSOK
The water circuit is empty. PressOKtodeliverwaterfromthespoutuntilitowsout
normally.