GB 18-01-2001 16:26 Pagina 1 OWNERS’ MANUAL PAC 210 U Portable Windowless Air-Conditioner 1
GB 18-01-2001 16:26 Pagina 2 IMPORTANT INFORMATION When using electrical appliances, basic safety precautions should always be followe, including the following: - Read all instructions. - To protect against fire, electrical shock and personal injury, do not immerse cord, plug or appliance in water or other liquid. - Close supervision is necessary when any appliance is used by or near children.
GB 18-01-2001 16:26 Pagina 3 Dear user, We thank you for purchasing the Pinguino air-conditioner and congratulate you on your wise choice. For optimal results please read this manual carefully before installing or operating. We know that the Pinguino will maintain your environment pleasingly comfortable at all times. With best wishes De Longhi S.p.A. If you have any questions about the operation or service of your Pinguino, please call our toll-free service number 1-800-322-3848.
GB 18-01-2001 16:26 Pagina 4 SPECIFICATIONS Power supply voltage V Frequency Hz 60 see rating label Cooling capacity: (*) 2 Fan speeds 360 cu.m/h Max. air flow capacity Dehumidification quotient (*) Dimensions: see rating label width height depth Net weight see rating label in. (mm) in. (mm) in. (mm) lb. (kg) 221/31 30 159/16 (560) (735) (390) 97 (44) *Data according to pending standard testing procedures subject to review by the U.S. Dept. of Energy.
GB 18-01-2001 16:26 Pagina 5 ILLUSTRATED MAIN FEATURES LIST Air outlet grid Timer cover (to adjust the timer slide cover sideways) Castor Castor stops Water collecting tray Air filter Air intake grid Exaust hose Power cable comp.
GB 18-01-2001 16:26 Pagina 6 ILLUSTRATED ACCESSORY LIST Table 1 DESCRIPTION ACCESSORY CHECK Check that all parts listed in Table 1 are included.
18-01-2001 16:26 Pagina 7 PERMANENT INSTALLATION The Pinguino accessories include two sets of flanges and stoppers, to be mountedl in different locations (two different rooms). Once installed, these vents (flanges) are the only items needed for using Pinguino. fig. 1 Permanent installation outlet holes must be in an exterior wall and opening diameter should not exceed 3”1/2. OUTSIDE INSIDE ,, ,, ,, fig. 2 INSIDE A1 in a window pane OUTSIDE 3”1/2 3”1/2 INSIDE fig.
GB 18-01-2001 16:26 Pagina 8 TEMPORARY INSTALLATION Note: In both cases (permanent and temporary installations) make sure that the Pinguino is positioned on level ground. If necessary use the two caster stops for the front casters This installation makes it easy to use Pinguino in any room, provided there is a window or a door: it allows you to use the Pinguino immediately. Suction discs may be used to keep window or door closed. Pinguino is equipped with an adjustable window bracket.
GB 18-01-2001 16:26 Pagina 9 ELECTRICAL CONNECTION Check that the power supply voltage is 115 V ~ 60 Hz. Important: if you need to use and extension cord, please be sure to use a heavy duty extension cord (minimum 14 gauge). Before connecting the Pinguino to power supply, make sure that all switches on the front control panel are in the OFF position. Connect power cord found in storage compartment at rear of the Pinguino. fig.
GB 18-01-2001 16:26 Pagina 10 DESCRIPTION OF PINGUINO PAC 210 U CONTROLS ON/OFF button ON/OFF pilot light A B C “Alarm” pilot light Timer ON/OFF pilot light Timer notches Thermostat SETTING THE TIMER The programmer/timer, like all clocks, must be set to the exact time. If for example it is 4.00 p.m., turn the dial in a clockwise direction (following the direction of the arrow) until the number 4 is lined up with the arrow pointer (the arrows indicates 4:00 p.m. approximately).
GB 18-01-2001 16:26 Pagina 11 HOW TO START UP THE CONDITIONER (see control panel on the previous page) Plug the appliance into the mains. Select the “programmed” or “non programmed” mode (see previous page) Select the fan speed required pressing “Fan speed” key C. AIR-CONDITIONING Key A ON/OFF (conditioning) must be released Turn the thermostat to Max. Cold. Press key A (ON/OFF). ON/OFF signal lamp (conditioning) will come on. The appliance comes on. If not, refer to pag. 14.
GB 18-01-2001 16:27 Pagina 12 MAINTENANCE PRECAUTIONS fig. 14 fig. 15 During cleaning and normal maintenance operations remember to disconnect plug. Under no circumstances should appliance be washed with runing water. Damage could be caused to the electrical circuit. ¢¢ ,, QQ ,, QQ ¢¢ CLEANING OF EXTERNAL HOUSING Use only mild soap and water. Do not use chemical cleaners. fig. 16 Clean with a damp cloth and dry thoroughly with a clean dry cloth. fig.
GB 18-01-2001 16:27 Pagina 13 AIR FILTER CLEANING Maintenance of air filter A clogged air filter reduces the quantity of circulating air and the efficiency of the appliance. Clean filter every week using a vacuum cleaner. fig. 19 Remove dust with a vacuum cleaner Removal and replacement of air filter Gently pull filter upwards. Push down to replace. fig. 20 Rinse with running water fig. 21 Cleaning procedure To remove dust deposited on filter, use a vacuum cleaner.
GB 18-01-2001 16:27 Pagina 14 TROUBLESHOOTING SYMPTOMS CAUSE SOLUTION The Pinguino does not function: - power failure plug is disconnected ON/OFF switch is off Timer key is in STOP position - insert plug switch on release the TIMER key - exhaust hose blocked - - exhaust hose twisted or bent ventilation holes on the rear of the machine or front louvers blocked - Check for obstruction of air outlet vent eliminate irregularities remove obstacles to allow proper airflow - - close window re-i
GB 18-01-2001 16:27 Pagina 15 FOR UNITED STATES ONLY: LIMITED WARRANTY We warrant each DE’LONGHI AIR-CONDITIONER to be free from defects in material and workmanship. Our obligation under this warranty is to provide one year parts and labor free from purchase date, with an additional four (4) years on any part of the sealed system consisting of the compressor, evaporator, condenser and factory connected refrigerant tubing.
GB 18-01-2001 16:27 16 Pagina 16
GB 18-01-2001 16:27 Pagina 17 17