5715111521_00/11.
C Series PORTABLE AIR CONDITIONER Instructions for use. Keep these instructions Visit www.delonghiregistration.com to register your product Visit www.delonghi.com for a list of service centers near you. ELECTRIC CHARACTERISTICS 120 V~ 60 Hz 900 W CONDITIONNEUR D’AIR PORTATIF Mode d’emploi . Conservez cette notice Visitez www.delonghiregistration.com pour enregistrer votre produit en ligne. Visitez www.delonghi.com pour y voir une liste des centres de réparation proches de chez vous.
INDEX Important safeguards............................................................4 Description.............................................................................5 Use.........................................................................................5 Control panel.........................................................................7 Turning the appliance on.......................................................7 Self-diagnosis.......................................................
DESCRIPTION 2 5 1 4 6 7 8 9 3 10 11 15 14 3 12 13 16
Important safeguard • • • • • • • • • • • • • • • • Use this appliance only as described in this instruction manual. As with any electrical appliance, the instructions aim to cover as many situations as possible. Caution and common sense should be used when operating and installing this air conditioner. This appliance has been manufactured to cool and dehumidify domestic environments and must not be used for other purposes. It is dangerous to alter or modify the unit's characteristics in any way.
INTRODUCTION Thank you for choosing a De’Longhi product. Please take a few moments to read the instructions to avoid risks or damage to the appliance.
G D in the window panel • If the windows are large, use the window bracket extension (16) (if provided) to cover your window aperture, extending it to the required length, then blocking it with the locking pins supplied (see figure E). Make sure you do not cover the hole for the window outlet. E • • 3 2 • 1 in the wooden kickboard of a French window in the wall: you are recommended to insulate the section of wall using suitable insulation.
CONTROL PANEL C I L M F G R H N D E B O P A Q DESCRIPTION A B C D E F G ON/STAND-BY button MODE selection button: Air conditioning, dehumidifying, fan.
The most suitable temperature for the room during the summer varies from 75°F to 81°F (24 to 27°C). You are recommended, however, not to set a temperature much below the outdoor temperature DEHUMIDIFYING MODE Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc). In dehumidifying mode, the appliance MUST be set-up in the same way as for air conditioning, with the air exhaust hose attached to enable the moisture to be discharged outside.
accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: - Reorient or relocate the receiving antenna.
Two arrows on the display indicate respectively air-conditioning “COOL” and the fan speed.The most suitable temperature for the room during the summer varies from 75 to 80°F (24 to 27°C). You are recommended, however, not to set a temperature much below the outdoor temperature. DEHUMIDIFYING MODE Ideal to reduce room humidity (spring and autumn, damp rooms, rainy periods, etc). In dehumidifying mode, the appliance selects fan speed automatically.
Precautions Never use petrol, alcohol or solvents to clean the appliance. Never spray insecticide liquids or similar products. close blinds or curtains • • • Never rest objects of any kind on the air conditioner. Never obstruct the air intake (6) or outlet (1) grilles. Minimize the number of heat sources in the room. CLEANING THE AIR FILTERS To keep your air conditioner working efficiently, you should clean the dust filter every week of operation. The filter is housed in the intake grille.
NOTE: NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit has been on its side, oil needs to return to the compressor to ensure proper function. Without allowing the unit this time (624 hours) the unit may function for only a short time, and then the compressor will break down from lack of oil. TROUBLESHOOTING PROBLEM CAUSE The air conditioning unit does not No electricity. start.
TECHNICAL SPECIFICATIONS Power supply voltage see rating label Max. absorbed power during air conditioning “ Refrigerant “ Cooling capacity “ LIMIT CONDITIONS Room temperature for air conditioning 64 ÷ 95°F (18° ÷ 35°C) OPERATION OF THE SAFETY PLUG If the safety device incorporated in the plug trips and cuts off the power supply, check that the power cable and plug are not damaged. If the power cable is undamaged, to restore operation press the "RESET" button.
De’Longhi is the distributor of Kenwood home appliances. This warranty applies to all home appliances with De’Longhi or Kenwood brand names LIMITED WARRANTY We warrant each De’Longhi AIR CONDITIONER to be free from defects in material and workmanship.