Use and Care Manual
12
NOTE:
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE DOWN OR
ON ITS SIDE. IF THIS OCCURS, WAIT 6 HOURS BEFORE TURNING
THE APPLIANCE ON, 24 HOURS IS RECOMMENDED. After the unit
has been on its side, oil needs to return to the compressor to
ensure proper function. Without allowing the unit this time (6-
24 hours) the unit may function for only a short time, and then
the compressor will break down from lack of oil.
TROUBLESHOOTING
PROBLEM CAUSE REMEDY
The air conditioning unit does not
start.
No electricity.
It is not plugged into the outlet.
The safety device of the plug has tripped.
Restore electricity.
Plug into the outlet.
Reset the safety device, if problem per-
sists contact our toll free customer service
The air conditioning unit works for a
short time only.
The air exhaust hose has a constriction.
The air exhaust hose is blocked.
There are tight bends in the air exhaust
hose.
Position the exhaust hose correctly.
Check there are no obstacles obstructing
air discharge.
Eliminate the tight bends.
The air conditioner works, but does
not cool the room.
Window open.
The exhaust hose is detached.
Air lters clogged.
Close the window.
Connect the exhaust hose.
Clean or replace the lters.
Bad odor in the room. The air purifying lters clogged. Clean or replace the lter.
The air conditioner does not operate
for about 3 minutes after turning it
on.
The internal compressor safety device
prevents the appliance from being
restarted until three minutes have
elapsed since it was last turned o.
Wait. This delay is part of normal
operation.
/ PF/ appears on the display.
The appliance has a self diagnosis system
to identify a number of malfunctions.
See the self-diagnosis chapter.