Instruction Manual

12
en
Technical specications
TECHNICAL SPECIFICATION
Power supply voltage see rating label
Max. absorbed power
during air conditioning
Refrigerant
Cooling capacity
LIMIT CONDITIONS
Room temperature for
air conditioning 64÷104°F18÷40°C
Transport, lling, cleaning, recovery and disposal
of refrigerant should be performed by a technical
service centre appointed by the manufacturer
only. The appliance should be disposed of by a
specialist centre appointed by the manufacturer
only.
NEVER TRANSPORT OR TURN THE APPLIANCE UPSIDE
DOWN OR ON ITS SIDE. IF THIS OCCURS, WAIT 6
HOURS BEFORE TURNING THE APPLIANCE ON, 24
HOURS IS RECOMMENDED. (After the unit has been on
its side, oil needs to return to the compressor to ensure
proper function. Without allowing the unit this time (6-
24hours)Theunitmayfunctionforonlyashorttime,and
then the compressor will break down from lack of oil).
Thisapplianceisequippedwitha 3 prong grounded
plug.Theplugmustbeconnectedintoanoutletthatis
properly installed and grounded in the accordance with
all local codes and ordinances. Do not modify the plug
provided with the appliance. If it will not t the outlet,
have a proper outlet installed by a qualied electrician or
relocate the unit to a proper outlet.
If the household electrical supply does not meet the
above specications, or if you are not sure your home
has an eective electrical ground, have a qualied
electrician or your local electrical utility company check
it and correct any problems.
SAFETY PLUG
Theapplianceisttedwithasafetyplugtoprotectthe
power cable.
If power is cut o, unplug from the outlet and make sure
the power cable is undamaged.
If the cable is damaged, call the service center
immediately.
If power cuts o frequently and the power cable is
undamaged, contact a qualied electrician.
OPERATION OF THE SAFETY PLUG
If the safety device incorporated in the plug trips and cuts
o the power supply, check that the power cable and
plug are not damaged.
If the power cable is undamaged, to restore operation
press the “RESET” button.
To verify correct operation of the plug, press the
TEST button periodically and make sure the appliance
disconnects. If this is not the case, contact the service
center.
Torestoreoperation,press the “RESET button.