VENTILATION FAN MODEL 80F/80-120DS/100F/100HS TABLE OF CONTENTS Package Contents 2 General Safety Information 3 Preparation 4 Assembly Instructions 5 New Construction 5 Existing Construction 6 Connect Wiring 7 Grille Installation 8 Operation 8 Care and Maintenance 9 Troubleshooting 10 Dimensions 11 Product Specifications 11 Warranty 12 READ AND SAVE THESE INSTRUCTIONS Address: 46101 Fremont Boulevard, Fremont, CA 94538 US Toll Free Number: 1-888-979-9889 www.deltabreez.
PACKAGE CONTENTS For all Models For Model of 80F/100F Quantity Part name Housing 1 Fan Body Duct Connector (4’’ ) 1 Grille 1 Tapping Screw (Ø4×25) 8 Machine Screw (#8-32x5/16’’) 4 Hanger Bar 4 Part name Appearance Appearance Quantity 1 For Model of 80-120DS Part name Appearance Fan Body Quantity 1 For Model of 100HS Part name Fan Body Appearance Quantity 1 (All images are not shown in actual scale) 2
GENERAL SAFETY INFORMATION READ AND SAVE THESE INSTRUCTIONS 1. Make sure that the electric service supply voltage is AC 120V, 60Hz. 2. Follow all local electrical and safety codes, as well as the National Electrical Code (NEC) and the Occupational Safety and Health Act (OSH Act). 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit lnterrupter) – protected branch circuit. 3.
PREPARATION Tools Required for Assembly (not included): Hammer, Flathead Screwdriver, Wire Nuts, Nails, Duct Tape, Phillips Head Screwdriver, Utility Knife. Short piece of flexible duct helps alignment and absorbs sound Helpful Tools (not included): Electric Drill, Drill Bits. Fan housing WARNING: Turn off electricity at breaker box before beginning installation. or Carefully remove unit from carton.
ASSEMBLY INSTRUCTIONS NEW CONSTRUCTION BEFORE INSTALLATION Turn off power source. Review all safety precautions. 1 MOUNT HOUSING WITH FLANGE: Tab 1. To bend the housing tabs out to 90 degrees and make housing tabs contact the bottom of the joist. Joist 2 2. The housing mounts with 4 tapping screws (ø 4x25). Screw housing to joist through lowest holes in each mounting flange, then through the other holes. Joist Tapping Screw USING HANGER BARS 3 3. Insert hanger bars into the channels on housing.
ASSEMBLY INSTRUCTIONS (Continued) b EXISTING CONSTRUCTION–ACCESSIBLE FROM ABOVE a 1. Measure the existing ceiling opening or cut a new opening to ensure it is large enough to accommodate a the new fan (8 in. x 8.25 in. suggested). 1 2. Place housing in opening so that its bottom edge is flush with finished ceiling. Screw housing to joist through lowest holes in each mounting flange. 2 in". 9.4 8.25 n.4." 8 9i Joist Screw Ø4×25 3.
ASSEMBLY INSTRUCTIONS (Continued) 2 2. Unplug fan connector from junction box. Remove fan body from housing. Screws 3 3. Insert the duct (not provided) into the duct connector and tape all ductworks connection to make them secure and airtight by through the ceiling opening. Using wire nuts (not provided) connect house wires to fan wires as shown in the connect wiring diagram on page 8. 4 4. Insert housing into ceiling opening and secure housing by using tapping screws (ø 4×25mm).
ASSEMBLY INSTRUCTIONS (Continued) GROUND (bare) SWITCH BOX JUNCTION BOX BLACK ON WHITE ON/OFF SWITCH (purchase separately) OFF FAN SWITCH GREEN BLACK WHITE SWITCH BOX L N WIRING PLATE FAN SWITCH G RD 120 VAC LINE IN GRILLE INSTALLATION Insert the mounting springs into the slots and mount the grille to the fan body. Slot Grille Spring OPERATION 2 1. For Model of 80F/100F Turn on the fan switch to operate ON. 2. For Model of 80-120DS Full Speed Mode: Turn on the fan to operate ON.
CARE AND MAINTENANCE TURN OFF POWER SOURCE. REVIEW ALL SAFETY PRECAUTION. See safety information before proceeding. Routine maintenance should be done at least once a year. • Never use solvents, thinner or harsh chemicals when cleaning the fan. • Do not allow water to enter the motor. • Do not immerse metal parts in water. 1 • Do not immerse resin parts in water over 140º F. 1. To remove grille, squeeze springs and pull down. Wash and clean grille with non-abrasive kitchen detergent.
TROUBLESHOOTING PROBLEM The fan is not turning on The fan seems louder than it should POSSIBLE CAUSE CORRECTIVE ACTION 1. Power off 1. Make sure power supply is on. 2. Faulty switch 2. Test or replace switch. 3. Faulty wire connection 3. Check wire in switch box. 1. CFM too great 1. Be sure the CFM rating on the fan matches the size of your room. 2. Damper not working properly or damaged 2. Check damper to ensure it is opening and closing properly.
DIMENSIONS " 14 8" 8 10 3 4 " 4" 10 3 4 " 5 34" PRODUCT SPECIFICATIONS Model No. Voltage Frequency Air Flow @ 0.1"SP Power @ 0.1"SP (V) (Hz) (CFM) (W) Max Current (Amps) Weight (lb.) Note 80F / VFB080C4A2 120 60 80 10.5 0.22 5.6 Single Speed 100F / VFB100C4A1 120 60 100 12.6 0.22 5.6 Single Speed 100HS / VFB100C4H1 120 60 100 12.6 0.24 5.7 Humidity Sensing 80-120DS / VFB120C4X1 120 60 120 21.6 80 7.3 0.38 5.
WARRANTY DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY Delta Electronics Inc. (“Delta Electronics”) warrants to the original consumer purchaser in the USA and Canada that the Breez ventilation fan products will be free from defects in material or workmanship. This warranty is limited to three (3) years from the original date of purchase. Limitations and Exclusions 1. During the warranty period, a replacement for any defective product will be supplied free of charge for installation by the consumer.