MODEL 110LED-ADJ
BreezSignature 110LED-ADJ
4” Duct (Standard)
Static Pressure (inches w.g.)
0.1
0.25
Air Flow (CFM)
110
94
Sones
0.4
0.8
Power Consumption (Watts)
14.8
17.3
Energy Efficiency (CFM/Watt)
8.4
6.0
Current (Amps)
0.48 Max
Power Rating (V/Hz)
120 / 60
LED Light (Watt)
13
(Fan/LED Light – 110 CFM)
Description
Low noise ceiling mount ventilating fan/Dimmable LED light
rated for continuous running. Fan has been ENERGY STAR
qualified, HVI, UL and cUL certified, and can be used to comply
with ASHRAE 62.2 (local and whole building continuous and
intermittent operation).
DC Motor/Blower
Power Rating of 120 volts/60Hz
DC brushless motor engineered to run continuously
Motor equipped with thermal cutoff fuse
Removable with permanently lubricated plug-in motor
Built-in soft start function to increase bearings’ life
Automatically powers OFF when impeller is locked
abnormally
Housing
Galvanized steel body
Detachable 4” diameter metal duct adapter
Built-in backdraft damper
Easy installation with expandable extension bracket
Grille
Attractive design using ABS material
Attaches directly to housing with torsion springs
Light
13-Watt LED light included (equivalent to a 60-Watt
incandescent bulb)
Light output 850 Lumens, 90CRI, 2700K, 4000k, 5000k
(adjustable color temperature)
Dimmable Lighting(dimmer switch not included)
Warranty
3-Year limited warranty
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model 110LED-ADJ;
ENERGY STAR qualifi¬ed with Brushless DC Motor engineered
to run continuously for a minimum 70,000 hours; airflow rating
of 110 CFM and loudness rating of 0.4 Sones at 0.1 static
pressure as certifi¬ed by the Home Ventilating Institute (HVI);
power consumption of 14.8 Watts with efficiency rating of 8.4
CFM/Watt at 0.1” static pressure; fan will feature motor lock
protection and self-compensating motor speed for intended
airflow when static pressure is encountered. UL and cUL listed
for tub/shower enclosure when used with GFCI-protected
branch circuit wiring.
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
4” Duct (Standard):
110 CFM/0.4 Sones @ 0.1” SP, 14.8 Watts
94 CFM/0.8 Sones @ 0.25” SP, 17.3 Watts