Using wire nuts (not provided), connect house
power cable to ventilating fan.
Connect wires are shown in wiring diagrams.
14 AWG (2.1 mm ) is the smallest conductor that
shall be used for branch-circuit wiring.
3.
4.
2
OFF
ON
JUNCTION BOX
SWITCH BOX
FAN SWITCH
WHITE
BLACK
GREEN
GRD
L
N
BLACK
WHITE
GROUND
(bare)
WIRING
PLATE
120 VAC
LINE IN
FAN
SWITCH
SWITCH BOX
ON/OFF SWITCH
(purchase separately)
1.
Models: 80F/100F/80-120DS/100HS
Insert the mounting springs into the slots and mount
the grille to the fan body.
GRILLE INSTALLATION
Slots
Spring
Grille
1.
Follow all local electrical and safety codes,
ANS1/NFPA70.
TURN OFF POWER SOURCE.
REVIEW ALL SAFETY PRECAUTION.
CONNECT WIRING
2.
NEVER place a switch where it can be reached
from a tub or shower.
1.
OPERATION
For Model of 80F/100F/80F-DGL
Turn on the fan switch to operate ON.
2.
Model: 80F-DGL
2.
For Model of 80-120DS
Full Speed Mode: Turn on the fan to operate ON.
The LED indicator light will be AMBER.
Slots
Spring
Grille
AMBER LED Indicator Light
(Full Speed Mode)
Low Speed Mode: Cycle ON/OFF fan switch to
operate LOW speed mode. The LED indicator
light will be GREEN.
GREEN LED Indicator Light
(Low Speed Mode)
3.
For Model of 100HS
Humidity Sensing Mode: Turn on the fan to
operate ON. The LED indicator light will be BLUE.
The fan will automatically start when the humidity
level in the room is above 60%. If humidity level is
below 60%, the fan will stop automatically.
BLUE LED Indicator Light
(Humidity Sensing Mode)
Full Speed Mode: Cycle ON/OFF fan switch to
operate at full speed mode. The LED indicator
light will be AMBER.
AMBER LED Indicator Light
(Full Speed Mode)
Full Speed Mode Only
(NO HUMIDITY SENSING MODE):
Locate humidity sensor inside housing (small black
box with LED indicator). Loosen screws around
sensor box and unplug the cable to disconnect.
CARE AND MAINTENANCE
See safety information before proceeding. Routine
maintenance should be done at least once a year.
Never use solvents, thinner or harsh chemicals
when cleaning the fan.
Do not allow water to enter the motor.
Do not immerse metal parts in water.
Do not immerse resin parts in water over 140º
Fahrenheit.
1. To remove grille, squeeze springs and pull down.
Wash and clean grille with non-abrasive kitchen
detergent.
Then wipe dry with a new cloth.
2. Remove dust and dirt from the fan body with a
vacuum cleaner.
3. Using a cloth dampened with non-abrasive kitchen
detergent, remove dust and dirt from the fan body.
Then wipe dry with new cloth.
4. Replace the grille back onto the fan body.
Turn on fan switch to operate fan again.
TURN OFF POWER SOURCE.
REVIEW ALL SAFETY PRECAUTION.
Vacuum
cleaner