Installation Instructions

4
DIMENSIONS
Unit: Inches (mm)
PRODUCT SPECIFICATIONS
Note: Design and specifications subject to change without notice.
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
1.
During the warranty period, a replacement for any
defective product will be supplied free of charge for
installation by the consumer. The warranty provided
herein does not cover charges for labor or other
costs incurred in the troubleshooting, repair,
removal, and installation service.
All returns of defective parts or products must
include the product model number, and must be
made through an authorized Delta Electronics
distributor. Authorized returns must be shipped
prepaid. Repaired or replacement products will be
shipped by Delta Electronics F.O.B. shipping point.
Delta Electronics shall not be liable for any indirect,
incidental, consequential, punitive, or special
damages arising out of or in connection with
products use or performance, regardless of the
form of action whether in contract, tort (including
negligence), strict product liability or otherwise.
The warranty does not cover if user does not
comply with manufacturer’s installation manual.
To qualify for warranty service, you must notify
Delta Electronics at the address or telephone
number below.
Delta Electronics shall have no liability to the
original owner-user with respect to any defect
caused by abuse, misuse, neglect, improper
transportation or storage, improper testing,
improper installation, improper operation, improper
use, improper maintenance, improper repair,
improper alteration, improper modification,
tampering or accident of products or parts thereof,
or unusual deterioration or degradation of products
or parts thereof due to a physical environment
beyond the requirements of products’ specifications.
Delta Electronics Inc. (“Delta Electronics”) warrants to
the original consumer purchaser in the USA and
Canada that the Breez ventilation fan products will be
free from defects in material or workmanship.
This warranty is limited to three (3) years from the
original date of purchase.
Limitations and Exclusions
2.
3.
4.
5.
6.
Address: 46101 Fremont Boulevard, Fremont, CA 94538
US Toll Free Number:
1-888-979-9889 – Technical Support
1-877-685-4384 – Customer Sales Support
www.deltabreez.com
TROUBLESHOOTING
PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION
The fan is not turning on 1. Power off
2. Faulty switch
3. Faulty wire connection
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
The fan seems louder
than it should
1. CFM too great
2. Damper not working
properly or damaged
3. Bend in duct too close
to fan discharge
4. Fan discharge reduced to
fit smaller duct
5. Fan body not securely
attached
1. Be sure the CFM rating on the fan matches
the size of your room.
2. Check damper to ensure it is opening and
closing properly. If the damper has become
damaged, please call Customer Service.
3. Be sure you do not have any sharp bends in
duct closer than 18 in. to the fan discharge.
4. Use recommended size ducting to reduce
fan noise.
5. Be sure the fan is securely attached to your
ceiling joists.
The fan is not clearing
the room
1. Insufficient intake airfow
within room
2. Insufficient CFM
1. Be sure a door or window is slightly ajar or
opened to allow airflow. The fan is not able
to draw air out of the room without enough
airflow to draw in from.
2. Be sure the CFM rating on the fan matches
the requirements for your room size.
The fan keeps running
even though the house
humidity level is lower
than 60% RH
1. Our sensor tolerance
is +/-10% RH
2. Outdoor humidity is
back drafting to the fan
3. Indoor temperature level
1. Make sure power supply is on.
2. Test or replace switch.
3. Check wire in switch box.
80F-DGL
80F/100F/
100HS/
80-120DS
10
3
4
"
10
3
4
"
10
3
4
"
10
3
4
"
8
1
4
"
5
3
4
"
4
"
8
"
Model No. Voltage (V) Frequency (Hz) Air Flow @ 0.1"SP (CFM) Power @ 0.1"SP (W) Max. Current (Amps) Weight (lb.) Note
80F /
VFB080C4A2
120 60 80 10.5 0.22 5.6
Single Speed
80F-DGL /
VFB080C4A2-DGL
120 60 80 10.5 0.22 5.6
Single Speed
100F /
VFB100C4A1
120 60 100 12.6 0.22 5.6
Single Speed
100HS /
VFB100H1
120 60 100 12.6 0.24 5.7
Humidity
Sensing
80-120DS /
VFB120C4X1
120 60
120 21.6
0.38 5.7
Full speed
80
7.3 Low speed