MODEL 80HS
Fan with Humidity Sensor – (80 CFM)
4” Duct (Standard):
80 CFM/<0.3 Sones @ 0.1” SP, 7.2 Watts
56 CFM/0.8 Sones @ 0.25” SP, 9.3 Watts
BreezSignature 80HS
4” Duct (Standard)
Static Pressure (inches w.g.) 0.1 0.25
Air Flow (CFM) 80 56
Sones <0.3 0.8
Power Consumption (Watts) 7.2 9.3
Energy Eciency (CFM/Watt) 11.0 6.0
Current (Amps) 0.15 @110Vac
Power Rating (V/Hz) 110~220/50~60
Description
Low noise ceiling mount ventilating fan with humidity sensor
rated for continuous running. Fan has been awarded ENERGY
STAR® qualied. It is HVI, UL, and cUL certied to comply with
ASHRAE 62.2 local and whole building continuous and
intermittent operation. Meets CA Title 24 requirements.
DC Motor/Blower
• Power Rating of 110~220volts/50~60Hz
• Motor equipped with thermal cuto fuse
• Permanently lubricated plug-in motor
• Allows fan to operate in full speed mode or humidity
control mode by cycling ON/OFF switch
• Built-in soft start function to increase bearings’ life
• Automatically powers o when impeller is locked abnormally
Housing
• Galvanized steel body
• Detachable 4” diameter duct adapter
• Built-in backdraft damper
• Easy installation
Grille
• Attractive design using ABS material
• Attaches directly to housing with torsion springs
LED Indicator
• Blue and Amber LED indicator lights to show humidity
sensor and full speed modes
Warranty
• 3-Year limited warranty
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model 80HS; ENERGY
STAR qualied with Brushless DC Motor engineered to run
continuously for a minimum 70,000 hours; airow rating of
80 CFM and loudness rating of <0.3 Sones at 0.1“ static
pressure as certied by the Home Ventilating Institute (HVI);
power consumption of 7.2 Watts with eciency rating of 11
CFM/Watt at 0.1” static pressure; fan will feature LED indica-
tor running light, motor lock protection and self-compen-
sating motor speed for intended airow when static pressure
is encountered. UL and cUL listed for tub/shower enclosure
when used with GFCI-protected branch circuit wiring.
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0
0.25
0.10
0 30.0 60.0 90.0 120.0 150.0
50ft
40ft
30ft
20ft
10ft
Air Pressure (IN H
2
O)
Air Flow (CFM)
60
Humidity
70 80 90 100 (%RH)5040300
(CFM)
0
30
60
90
120
150
Air Flow
Humidity ControlFan Curve
9 ⁄”
9 ⁄”
8”
4”
12
⁄
”
12
⁄
”