Technical Specifications

Fremont, CA 94538 | tel 1.888.979.9889 | www.deltabreez.com
Model
Quantity
Comments
Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
46101 Fremont Blvd.,
MODEL 80HS
Fan with Humidity Sensor – (80 CFM)
4” Duct (Standard):
80 CFM/<0.3 Sones @ 0.1” SP, 7.2 Watts
56 CFM/0.8 Sones @ 0.25” SP, 9.3 Watts
BreezSignature 80HS
4” Duct (Standard)
Static Pressure (inches w.g.) 0.1 0.25
Air Flow (CFM) 80 56
Sones <0.3 0.8
Power Consumption (Watts) 7.2 9.3
Energy Eciency (CFM/Watt) 11.0 6.0
Current (Amps) 0.15 @110Vac
Power Rating (V/Hz) 110~220/50~60
Description
Low noise ceiling mount ventilating fan with humidity sensor
rated for continuous running. Fan has been awarded ENERGY
STAR® qualied. It is HVI, UL, and cUL certied to comply with
ASHRAE 62.2 local and whole building continuous and
intermittent operation. Meets CA Title 24 requirements.
DC Motor/Blower
Power Rating of 110~220volts/50~60Hz
Motor equipped with thermal cuto fuse
Permanently lubricated plug-in motor
Allows fan to operate in full speed mode or humidity
control mode by cycling ON/OFF switch
Built-in soft start function to increase bearings’ life
Automatically powers o when impeller is locked abnormally
Housing
Galvanized steel body
Detachable 4” diameter duct adapter
Built-in backdraft damper
Easy installation
Grille
Attractive design using ABS material
Attaches directly to housing with torsion springs
LED Indicator
Blue and Amber LED indicator lights to show humidity
sensor and full speed modes
Warranty
3-Year limited warranty
TYPICAL SPECIFICATION
Ventilation fan shall be Delta Breez model 80HS; ENERGY
STAR qualied with Brushless DC Motor engineered to run
continuously for a minimum 70,000 hours; airow rating of
80 CFM and loudness rating of <0.3 Sones at 0.1“ static
pressure as certied by the Home Ventilating Institute (HVI);
power consumption of 7.2 Watts with eciency rating of 11
CFM/Watt at 0.1” static pressure; fan will feature LED indica-
tor running light, motor lock protection and self-compen-
sating motor speed for intended airow when static pressure
is encountered. UL and cUL listed for tub/shower enclosure
when used with GFCI-protected branch circuit wiring.
0.90
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0
0.25
0.10
0 30.0 60.0 90.0 120.0 150.0
50ft
40ft
30ft
20ft
10ft
Air Pressure (IN H
2
O)
Air Flow (CFM)
60
Humidity
70 80 90 100 (%RH)5040300
(CFM)
0
30
60
90
120
150
Air Flow
Humidity ControlFan Curve
9 ⁄”
9 ⁄”
8”
4”
12
⁄
12
⁄

Summary of content (1 pages)